CONNECTING A PELCONET TRANSMITTER TO THE CM6800 ASCII PORT
Refer to the transmitter portion of Figure 56. This configuration lets an operator view and control cameras from a PC using a web browser. (The
operator’s PC is not shown on the diagram.) All settings are done in the CM6800 manager program or through a CM6800 menu. Note the
following:
operator’s PC is not shown on the diagram.) All settings are done in the CM6800 manager program or through a CM6800 menu. Note the
following:
•
Port 2 defaults to ASCII and RS-232.
•
Ports 7 and 8 can be set to ASCII and RS-232 by using the CM6800 manager program (refer to Figure 54) or by using a CM6800 menu (refer
to Figure 55).
to Figure 55).
•
Port 2 is recommended.
Figure 54. Manager Screen
Figure 55. Menu Screen
SET SERIAL PORT 07
DEVICE:
ASCII
TYPE:
RS232
BAUD RATE:
9600
PARITY:
ODD
DATA BITS:
8
STOP BITS:
1
RETURN