ADVANCED OPERATION 
 
 
Alarm System 
In the event of a misfire the LED display will blink bFL (see page 7).  The alarm system is 
reset automatically by flashing the unit or by pressing any button on the control panel. 
 
 
Thermal Protection 
The ML600 is protected with an internal overtemp cutout. In the event of an overtemp, the 
modeling light will be disabled.  
 
 
 
SERVICE 
 
 
Should not be attempted by user.  Consult an authorized Norman Service Center. 
 
Modeling lamp or flashtube replacement.  Always unplug unit and discharge stored energy 
by pressing the Test button.  Wait 10 minutes for any residual charge on the main capacitors to 
bleed off and let the flashtube and modeling lamp cool before handling.  Always handle 
modeling lamp with clean gloves or cloth to avoid transfer of body oils to lamp dome.  
Carefully remove old flashtube and/or modeling lamp and replace with new. 
 
Never place metal object or fingers into modeling lamp or flashtube sockets. 
 
 
 
DIAGNOSTIC TROUBLESHOOTING / ERROR CODES 
 
 
This information can assist the operator in determining the source of a malfunction and it can 
assist an authorized Norman service center in servicing a Norman Monolight.  These codes 
flash on the LED Display, signifying the following: 
 
General Errors 
 
bFL –
 Indicates a misfire.  Check if flashtube is installed, flashtube may need replacement. 
 
hot –
 Indicates internal temperature has exceeded  normal operating limits. Modeling lamp 
will be disabled and automatically enabled when internal temperature returns to normal 
operating range.  
 
 
 
 
 
 
 
 
8
GENERAL TROUBLESHOOTING 
 
 
Unit will not flash: 
 
Flashtube is not installed properly. (see page 4) 
 
Sync cord polarity not correct (see ‘SYNC Outlet’ page 6) 
 
Unit does not turn on: 
 
Check power cord 
 
Check circuit breaker 
 
Photo Eye does not flash unit: 
 
Sync cord is plugged in (see page ‘Photo Eye’ page 6) 
 
Trigger flash is out of range 
 
Modeling light will not turn on. 
 
Modeling lamp is not installed properly (see page 4) 
 
Modeling lamp is broken 
 
Modeling lamp is turned off.  Check the control panel switches (see page 5) 
 
Note: If you are still experiencing trouble after checking the above general troubleshooting 
guideline contact Photo Control Customer Service.  
 
 
 
SPECIFICATIONS 
 
Power: 
  600 
W-S 
Recycle Time: 
 
2 sec. 
Flash Duration: 
 
1/1200 sec. (full) 
Power Control: 
 
Full to -5 F-Stops 
Modeling Lamp: 
 
250W 
Modeling Lamp Control: 
Off, Ratio, Full 
Trigger:   
 
Built-in Photo-eye, ¼” Sync Jack, Test Button 
Supply Voltage: 
 
105-125 VAC, 60Hz, 10A 
Consumption:  
10A 
Voltage Stabilization: 
+/- 1% 
Overload Protection: 
10A Circuit Breaker 
Weight: 
  6.14 
Lbs. 
Flashtube:   Quartz, full envelope 
Guide Number: 
 
135 at 10 ft., ISO100, Bare Bulb 
Sync Voltage: 
 
6 VDC 
 