Справочник Пользователя для National Instruments NI VISION PCI-8254R

Скачать
Страница из 43
Chapter 2
Hardware Overview
© National Instruments Corporation
2-13
Figure 2-5.  Connecting isolated input to a sourcing output device
Wiring an Isolated Output to an External Load
The digital output circuit sources current to external loads, as shown in 
Figure 2-6.
Caution
Do not draw more than 100 mA from 24 V or 30 V isolated outputs. Do not draw 
more than 50 mA from 5 V isolated outputs.
Figure 2-6.  Digital output sources current to external loads
Vcc
Sourcing
Output
Device
V
Current
Limiter
C
NI 8254R
Input
Digital Output
V
C
Vcc
NI 8254R
Load