Справочник Пользователя для Force10 Networks Force10 TeraScale E-Series E1200i

Скачать
Страница из 105
Installing and Maintaining the E1200i System
89
SFMs and Alarms
The number of SFMs present in the system when it boots determines the level of alarms sent when a tenth 
(redundant) SFM is removed or fails. At boot time, if ten SFMs are present and functioning, the E1200i 
system issues no alarms. However, if one SFM fails or is removed, the system sends a minor alarm stating 
that nine SFMs are present. The system requires eight functioning SFMs to pass traffic. 
At boot time, if eight SFMs are present and functioning, the E1200i system issues no alarms. The system 
issues no alarms if an SFM is added to the system; however, if the number of functioning SFMs changes 
from nine to eight, the system sends a minor alarm event. The system always triggers a major alarm when 
the number of working SFMs reaches seven.