Справочник Пользователя для Force10 Networks Force10 TeraScale E-Series E1200i

Скачать
Страница из 105
94
System Specifications
Environmental Specifications
Agency Compliance
The E1200i is designed to comply with the following safety and agency requirements.
USA Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 
15 of the FCC rules. These limits are designated to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy. If it is not installed and used in accordance to the instructions, it may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 
interference, in which case users will be required to take whatever measures necessary to correct the interference 
at their own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Force10 
Networks is not responsible for any radio or television interference caused by using other than recommended 
cables and connectors or by unauthorized changes or modifications in the equipment. Unauthorized changes or 
modification could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation.
Canadian Department of Communication Statement 
European Union EMC Directive Conformance Statement
This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the 
approximation of the laws of the Member States relating to electromagnetic compatibility. Force 10 Networks can 
not accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended 
modification of this product, including the fitting of non-Force10 option cards.
This product has been tested and found to comply with the limits for Class A Information Technology Equipment 
according to CISPR 22/European Standard EN 55022. The limits for Class A equipment were derived for 
Operating
Specifications 
Temperature
32° to 104°F (0° to 40°C)
Maximum altitude
No performance degradation to 10,000 feet (3,048 meters)
Relative humidity
5 to 85 percent, noncondensing
Shock
Designed to meet Telcordia GR-63 CORE
Vibration
Designed to meet Telcordia GR-63 CORE
Non-operating
Temperature
-40° to 158°F (-40° to 70°C) 
Maximum altitude
15,000 feet (4,572 meters)
Relative humidity
5 to 95 percent, noncondensing
Vibration
Bellcore GR-63