Справочник Пользователя для DSCover Satellite Products Home Security System PC1555MX
1
Section 1: System Introduction
1.1
Specifications
Downloading Software Support
•
•
PC1555MX v2.3 uses DLS-3 v1.3 and higher.
Flexible Zone Configuration
•
•
Six fully programmable zones
•
System expandable to 32 zones using:
•
up to 8 keypad zone inputs and/or
•
up to 32 wireless zones with the PC5132 wireless
expansion module
expansion module
•
38 access codes: one master code, one maintenance
code, two duress codes, two supervision codes and 32
general access codes
code, two duress codes, two supervision codes and 32
general access codes
•
27 zone types; 8 programmable zone attributes
•
Normally closed, single EOL and double EOL zone wiring
•
32 wireless zones with the PC5132 Wireless Receiver
Audible Alarm Output
•
•
700mA Supervised Bell Output (current limited at 3A), 12V
DC
•
Steady or Pulsed Output
EEPROM Memory
•
•
Does not lose programming or system status on complete
AC and Battery failure
AC and Battery failure
Programmable Outputs
•
•
One programmable voltage output and one programmable
voltage output/input; 23 programmable options
voltage output/input; 23 programmable options
•
PGM1 = 50mA; PGM2 = 300mA (50/300 products)
•
PGM2 = 50mA; PGM2 = 50mA (50/50 products)
•
Eight additional low current (50mA) outputs available using
the PC5208 module
the PC5208 module
•
Four additional high current (300mA) outputs available
using the PC5204 module; one PC5204 output fully super-
vised for siren
using the PC5204 module; one PC5204 output fully super-
vised for siren
Powerful 1.5 Amp Regulated Power Supply
•
•
550 mA Auxiliary Supply, 12 V
DC
•
Positive Temperature Coefficient (PTC) components
replace fuses
replace fuses
•
Supervision for loss of AC power, low battery
•
Internal clock locked to AC power frequency
Power Requirements
•
•
Transformer = 16.5 V
AC
, 40VA
•
Battery = 12 volt 4 Ah minimum rechargeable sealed lead
acid battery
acid battery
•
For household fire and burglary installations, two 7Ah bat-
teries in parallel must be used, providing 24 hours of
standby power and 4 minutes of alarm output power.
teries in parallel must be used, providing 24 hours of
standby power and 4 minutes of alarm output power.
•
For commercial burglary installations, a 4Ah (or larger) bat-
tery must be used, providing at least 4 hours of standby
power and 4 minutes of alarm output power.
tery must be used, providing at least 4 hours of standby
power and 4 minutes of alarm output power.
WARNING: Do not install this panel outside of North America.
By design, this panel will not work if the AC line frequency
drops below 55.5Hz.
Remote Keypad Specifications
•
By design, this panel will not work if the AC line frequency
drops below 55.5Hz.
Remote Keypad Specifications
•
Keypads available:
- PC5508Z eight zone LED keypad with zone input
- PC5516Z sixteen zone LED keypad with zone input
- PC5532Z thirty-two zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
- LCD5501Z fixed message LCD keypad with zone input
- LCD5501Z32-900 keypad / receiver
- PC5508Z eight zone LED keypad with zone input
- PC5516Z sixteen zone LED keypad with zone input
- PC5532Z thirty-two zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
- LCD5501Z fixed message LCD keypad with zone input
- LCD5501Z32-900 keypad / receiver
•
All keypads have five programmable function keys
•
Connect up to eight keypads
•
4-wire (Quad) connection to Keybus
•
Built in piezoelectric buzzer
Digital Communicator Specifications*
•
•
Supports major communication formats including SIA and
Contact ID
Contact ID
•
Digital Communicator compatible receivers and their formats:
Silent Knight Model 9000: 3/1, 4/1, 4/2 non-extended, 3/1
extended, 20 bps, 1400 Hz handshake.
Ademco Model 685: 3/1, 4/1, 4/2 non-extended, 3/1
extended, 20 bps, 1400 Hz handshake, Contact ID.
Sescoa Model 3000: 3/1, 4/1, 4/2 non-extended, 3/1
extended, 20 bps, 1400 Hz handshake.
Radionics Model D6500: 3/1, 4/2 non-extended, 3/1
extended, with or without parity, 1400 and 2300 Hz hand-
shake.Sur-Gard Model MLR2-DG: 3/1, 4/1, 4/2, without parity,
20 bps, 1400 and 2300 Hz handshake, Contact ID, SIA.
Silent Knight Model 9000: 3/1, 4/1, 4/2 non-extended, 3/1
extended, 20 bps, 1400 Hz handshake.
Ademco Model 685: 3/1, 4/1, 4/2 non-extended, 3/1
extended, 20 bps, 1400 Hz handshake, Contact ID.
Sescoa Model 3000: 3/1, 4/1, 4/2 non-extended, 3/1
extended, 20 bps, 1400 Hz handshake.
Radionics Model D6500: 3/1, 4/2 non-extended, 3/1
extended, with or without parity, 1400 and 2300 Hz hand-
shake.Sur-Gard Model MLR2-DG: 3/1, 4/1, 4/2, without parity,
20 bps, 1400 and 2300 Hz handshake, Contact ID, SIA.
•
Event-initiated personal paging
•
Three programmable telephone numbers
•
Two account numbers
•
Supports LINKS1000 cellular communication
•
Supports LINKS2X50 long range radio transmitter
•
Supports Skyroute transceiver
•
DTMF and pulse dialing
•
DPDT line seizure
•
Anti-jam feature
•
Split reporting of selected transmissions to each telephone
number
number
System Supervision Features
The PC1555MX continuously monitors a number of possible
trouble conditions including:
•
The PC1555MX continuously monitors a number of possible
trouble conditions including:
•
AC power failure
• AUX Power Supply Trouble
•
Fault by zone
• Loss of internal clock
•
Tamper by zone
• Bell output trouble
•
Fire trouble
• Telephone line trouble
•
Failure to communicate
• Low battery condition (panel)
•
Low battery by zone (wireless)
•
Module fault (supervisory or tamper)
False Alarm Prevention Features
•
•
Audible Exit Delay
• Quick Exit
•
Audible Exit Fault
• Cross Zone Burglary Alarm
•
Communication Delay
• Rotating Keypress Buffer
•
Urgency on Entry Delay
• One Restart of Exit Delay
Additional Features
•
•
Auto Arm at specified time
•
Keypad-activated alarm output and communicator test
•
All modules connect to the system via a four wire Keybus
up to 1000’/305m from main panel
up to 1000’/305m from main panel
•
An event buffer which records the past 128 events with
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad and DLS-3 software
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad and DLS-3 software
•
Supports the addition of the PC5132 wireless receiver for
integration of wireless devices
integration of wireless devices
•
Uploading and downloading capability
•
Local downloading capability through the use of the
PC-Link adaptor
PC-Link adaptor
•
Supports the Escort5580 Voice Prompt Module with auto-
mation/lighting control
mation/lighting control
•
Supports the addition of the PC5928 Audio Interface Mod-
ule to integrate intercom stations
ule to integrate intercom stations
•
Added Keybus fault protection: clock and data outputs
have been programmed to withstand shorts to +12v to pre-
vent control panel damage
have been programmed to withstand shorts to +12v to pre-
vent control panel damage
*LINKS1000, LINKS2X50, and Skyroute have not been investigated by UL.
WWW.DIYALARMFORUM.COM