1.3.  Technical Characteristics 
 
Specification 
Description 
Power 
Four ‘AA’ Alkaline Batteries 
Warm-Up Time 
10 seconds 
Gases 
Detected 
Refrigerants:  All CFC, HCFC and HFC refrigerants 
including: R-12, R-22, R-123, R-134a and blends 
R-404A, R-408A, R-409A, and R-410A (i.e., any 
refrigerant containing Chlorine, Fluorine or Bromine 
gas). 
Combustibles:
Response Time 
  All combustible gases and vapors. 
0.2 seconds 
Sensitivity 
Refrigerants:  0.5 oz/year (14 g/yr) of R-134a 
(hardest to detect refrigerant) as detected by 
moving probe tip at 2" (50 mm) per second, 
0.1" (3 mm) above leak source. A leak rate of less 
than 0.25 oz/year (7 g/yr) can be detected when 
probe tip is held steady over leak source for at 
least 5 seconds. 
Combustibles:
Sensitivity 
Adjustment 
  50 ppm Methane, minimum. 
Automatic 
Battery Life 
4–5 hours, under typical intermittent operation 
Sensors 
Combustibles:  Semiconductor type with a typical 
5 year life span, plug-in replacement. 
Refrigerant:
Probe 
  Heated Diode type with a typical life 
span of 150 hours or 1 year of normal use, plug-in 
replacement. 
Flexible gooseneck, 20 inch (508 mm) maximum 
length [reduces to 3 inches (76 mm) when wrapped 
around instrument], includes integral sensor, filter, 
and LED 
Sampling 
System Flow 
Rate  
40 to 50 cc/min with sensor installed 
Weight  
0.86 lb (0.39 kg) w/ batteries