Chapter 4   Operation
- 29 -
4.6 Exposure
The machine has two exposure modes: remote exposure which performs
exposure using data provided from the host computer, and local exposure
which performs laser test exposure and re-exposure.
Remote exposure
After entering remote mode (ON LINE lamp is lit), give the exposure
command through the host computer (RIP computer).  While exposure is in
progress, "Exposing ***%" is displayed on the panel display.  "***%"
indicates the percentage currently exposed.
[Display during remote exposure]
The panel display changes as shown below during the exposure.
Local exposure
[Laser Test Expo.]
(1) Confirmation and input of the plate type, resolution and light intensity
1) Use the 
key to call up 
display.
2) Select
using the 
key and press the 
key.
3) Press the 
key while 
is displayed.
4) Plate type, resolution and light intensity are displayed.
(Example)
(F175 1200 dpi Light intensity 200)
5) Press the 
key to change the resolution. Select the desired
resolution from among 12 (1200 dpi), 15 (1500 dpi), 18 (1800 dpi)
and 24(2400dpi) using the 
key.  Register the resolution using
the key.
6) Press the 
key to move the cursor to the light intensity value
display and then press the 
key.
7) Change the light intensity value using the 
key or the 
key.
Press the 
key to register the light intensity value.
Press the 
key to return to the previous menu if no change is necessary or
setting is discontinued.
MENU
Note
ENT.
ENT.
ENT.
ENT.
F 1 7 5         ( 1   2 )           2 0 0
Laser Test Expo.
ENT.
ENT.
<Laser>
< Plate Data >
MENU
Data transmission start
Data transmission end
Data Transferring
Image data exposure start
Exposing        0%
Image data exposure end
Plate is being discharged
Exposing     100%
Discharging
Completion
Complete