Справочник Пользователя для Martin Fireplaces DMX Controller 2518

Скачать
Страница из 28
23
a p p e n d i x   a  
T
ROUBLESHOOTING
  
* To test the data link with an ohm meter, disconnect the link from the controller and
measure the resistance across pins 2 and 3 of the XLR male plug. The reading should
be around 120 ohms. Readings from 400 - 20,000 ohms indicate the data link is not
terminated. Infinite resistance indicates a bad connection, broken wire, or a defective
fixture. Very low readings indicate a short circuit in the link or a defective fixture. 
problem
probable cause(s)
suggested remedy
None of the fixtures 
respond to the controller.
The controller is discon-
nected from the data link.
Connect controller.
Blackout or standby mode 
selected.
Press blackout button.
Some fixtures do not 
respond, respond erratically, 
or continuously reset.
Bad data link connection.
Check data link connec-
tions/cables and correct 
accordingly.* 
DMX signal polarity 
reversed.
Swap pins 2 and 3. See 
section 2.
DMX signal reflection. 
Insert termination plug in 
the last light on the link.
Incorrect addressing of fix-
tures.
Check addresses. 
Fixtures not on.
Turn on fixtures.
Protocol auto-detection fail-
ure.
Switch the fixtures off and 
then back on. In general, 
power on the controller 
before the fixtures.
Save commands do not 
work.
Memory locked.
Unlock memory.
Fixtures do not execute pro-
gramming on one or more 
channels. 
Fader control is overriding 
programming. 
Turn off fader control. 
No light from some or all fix-
tures.
The scenes do not contain 
‘Lamp On’ instructions for 
fixtures with remote lamp 
on/off.
Make sure the “Lamp On” 
command is saved in at 
least one scene.
Uneven or incomplete fader 
control. 
Faders not calibrated.
Calibrate faders as 
described in “Service”.