Инструкции По Установке для Amana AGK01

Скачать
Страница из 20
13
3.
Run 6 to 8 wires during initial installation.  Tape or cap off any
unused wires.
DS1 DS2 MS1 MS2 EH IN
LS FD1 FD2 TF- TF+
C
R
GL W2 Y/W1 B
GH
REMOTE THERMOSTAT
AUXILIARY
X1
O
B*
*
Y
W1
W2
G*
R
Thermostat
 Connections
Control Board
Connections
Wiring Schematic for Straight Cool Unit
*NOTE:  For high speed fan operation, connect “G” to “GH”.
DS1 DS2 MS1 MS2 EH IN
LS FD1 FD2 TF- TF+
C
R
GL W2 Y/W1 B
GH
REMOTE THERMOSTAT
AUXILIARY
X1
O
B*
*
Y
W1
W2
G*
R
Thermostat
 Connections
Control Board
Connections
Wiring Schematic for  Remote Heat Pump
*NOTE:  For high speed fan operation, connect “G” to “GH”.
Table 5 shows the maximum wire length and corresponding gage
size for installation of a remote thermostat.
Maximum Wire 
Length
Wire Size 
(AWG)
Maximum Length 
Allowed
#24
400 ft
#22
600 ft
#20
900 ft
#18
1500 ft
#16
2000 ft
Table 5 - Maximum Wire Length for Remote
Control Connection
WARNING
T
O PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEATH DUE TO
ELECTRIC SHOCK, DISCONNECT THE ELECTRICAL POWER SUPPLY BEFORE
CLEANING THIS UNIT.
Operating Instructions
**If configured, B and O input terminals can be used interchangeably.