Fault indicators
In the case of a fault the following fault indicators are shown on the display. 
Troubleshooting
S3
J1
DISPLAY
S2
S1
Display
Cause
Action
Over flow fault, Overflow 
Fault, Over flow fault, 
Överfyllnad, Overløbsfejl, 
Overflom, Ylitulviminen, 
Trop plein, Überlauf, 
Troppo pieno, Desborde, 
Пeрeлив вoды, Te veel 
water
The microswitch is opened when a 
full condensed water tank is detected. 
Detection begins 30 seconds after the 
programme starts. If the microswitch is 
open >30 seconds the programme cycle 
is stopped.
Check whether the customer has:
• Emptied the tank and restarted the
   machine.
Service action:
• Clean hoses and check voltage and 
   resistance of drainage pump.
•  Check that the float has not got 
“stuck” and check the function of the 
microswitch.
The auto filter is clogged, defective or 
the auto filter/sealing is improper fitted.
Check whether the customer has:
• Cleaned the auto filter and installed the
   auto filter/sealing properly.
Service action:
• Replace the auto filter and/or the
   sealing.
H
(h
ea
t p
um
p)
Defective or improper installed anti-
siphon valve.
Service action:
• Clean the hose and replace the 
   anti-siphon valve.
The reversing valve is clogged or 
defective.
Service action:
• Clean the auto filter and replace 
   the anti-siphon valve.
Hoses improper installed after service.
Service action:
• Check hose installation.
Max Program Time, 
Max program time , 
Maximal programtid, 
Maksimal programtid, 
Maks programtid, Max 
ohjelma-aika, Durée maxi 
prog., Tijd overschreden, 
Tempo max. progr., 
Duración máx prog, 
Пpeвышeниe вpeмeни, 
Max. Programmzeit
The programme cycle time exceeds 200 
minutes. The cycle is stopped and the 
programme is reset.
High ambient temperature combined 
with low heater output and low 
drying temperature leads to poor 
condensation formation.
Poor condensation due to blocked 
external air
Check whether the customer has:
• Tried spinning at a higher 
   speed.
•  Had the machine switched off for 30 
minutes before restarting.
• Good ventilation in the room.
Service action:
• Ensure that the external air has free
   passage.
Service Manual TD70.C