Техническое Описание для Frigidaire FFTA1233Q1

Скачать
Страница из 3
RAC Through-The-Wall Models
Frigidaire Baseline
Specifications  
subject to change.
Plug Type (NEMA)
5-15P
Home Comfort Specifications
• 
Product Shipping Weight (approx.) – 83 Lbs.
• 
An electrical supply with grounded three-prong receptacle is 
required. The power supply circuit must be installed in accordance 
with current edition of National Electrical Code (ANSI/NFPA 70)  
and local codes & ordinances.
• 
Voltage Rating – 115V / 60 Hz / 15 Amps
• 
Amps @ 115 Volts = 11.5 Amps
• 
Recommended Circuit Breaker – 15 Amps
• 
Unit equipped with 115V 3-wire power supply cord, NEMA plug type 
5-15P, approximately 72" long.
• 
Unit’s increased performance characteristics result from two rear 
intakes. For unit to operate at maximum efficiency, carefully follow 
complete, detailed new or replacement installation instructions 
provided in Product Installation Guide on web.
• 
Unit requires rearward slope when installation is complete, to allow 
condensate to drain from rear of sleeve.
New Installation
• 
For new installation, Frigidaire® Through-The-Wall 18" Sleeve Kit  
PN # EA108T available. Recommended for proper installation.
• 
Through-the-wall installation requires 18" maximum wall thickness.
• 
For energy-saving purposes, install unit in shady location, preferably 
a northern exposure; and do not block airflow inside with blinds, 
curtains or furniture; or outside with shrubs, enclosures or other 
buildings.
Replacement Installation
• 
When replacing existing air conditioner with new unit, refer to 
Product Installation Guide on web to identify existing wall-sleeve 
manufacturer and size compatibility. If proper installation and slope 
are suspect, then correct installation of Frigidaire® Through-The-Wall 
18" Sleeve Kit PN # EA108T recommended.
• 
Use of existing wall sleeve to mount new unit requires original sleeve 
be in sound structural condition with rear grille that attaches securely, 
or rear flange that serves as stop for unit.
• 
Preferable installation option, for increased efficiency and possibility 
of drafts reduced, requires existing rear grille (mounted to sleeve) be 
replaced with new unit’s rear air-directional louvered grille (provided 
in accessory kit, shipped with unit). Non-preferable installation option 
of directly mounting rear louvered grille to unit can be considered, 
requiring grille be mounted to unit prior to sleeve installation.
• 
Existing decorative exterior grille may be left in place, provided that 
proper air-directional rear louvered grille is installed.
• 
For installation into larger existing sleeve, optional Trim Kit  
PN # EA120T available.
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.
Optional Accessories
• 
Through-The-Wall 18" Sleeve Kit – (PN # EA108T).
• 
Trim Kit (for larger existing sleeve) – (PN # EA120T).
• 
Architectural-Style Exterior Louvered Grille – (PN # EA109T).
USA
 • 
10200 David Taylor Drive
 • 
Charlotte, NC 28262
 • 
1-800-FRIGIDAIRE
 • 
frigidaire.com 
CANADA
 • 
5855 Terry Fox Way
 • 
Mississauga, ON L5V 3E4
 • 
1-800-265-8352
 • 
frigidaire.ca
FFTA1233Q1  01/14 
© 2014 Electrolux Home Products, Inc. 
Home Comfort
FFTA1233Q1
    Through-The-Wall Air Conditioner