Electrical Installation
The models stated on the front cover are either dual-
rated, designed to be connected to either 208/240V AC, 
60 Hz, 4-wire, single-phase power supply, or rated at 
120V AC, 60 Hz and use a NEMA 5-20 plug to connect 
to a dedicated 120 V microwave circuit.
208/240 V models may also be combined with some 
Bosch Built-in Ovens and can be connect directly to the 
combo appliance. To do this, please refer to detailed 
instructions with the Bosch Combination Kit.
9
WARNING
When connected to a 4 or 5-wire, 120/208-Volt 3-
phase power supply; the phase C conductor is not 
required for the operation of the appliance.
Electrical Connection with Plug
HMC87151UC
HMC80151UC
Electrical Requirements:
a three prong grounded outlet
120 V, 60 Hz, AC only
20 Amp electrical supply with a fuse or a circuit 
breaker
This product must be connected to a supply circuit of the 
proper voltage and frequency. Wire size must conform to 
the requirements of the National Electric Code or the 
prevailing local code for this rating. The power supply 
cord and plug should be brought to a separate 20-amp 
branch circuit single grounded outlet. The outlet box 
should be located in the area behind the appliance (see 
section Cabinet Dimensions). The outlet box and supply 
circuit should be installed by a qualified electrician and 
conform to the National Electrical Code or the prevailing 
local code.
The voltage used must be the same as specified on this 
microwave oven. Using a higher voltage is dangerous 
and may result in a fire or oven damage. Using a lower 
voltage will cause slow cooking. The dealer is not 
responsible for any damages resulting from the use of 
the oven with any voltage other than specified.
Electrical Connection with Wire Conduit
HMC80251UC
The electrical supply should be a 4-wire single-phase AC. 
Install a suitable conduit box (not furnished). An 
appropriately-sized, UL-listed conduit connector must be 
used to correctly attach the conduit to the junction box.
NOTICE:  Local Codes may vary; installation, electrical 
connections and grounding must comply with all 
applicable local codes.
If local codes permit grounding through the electrical 
supply neutral, connect both the white neutral wire and 
the bare ground wire from the oven to the white neutral 
electrical supply wire.
Electrical Connection
The four-wire connection is preferred, but where local 
codes permit, the three wire connection is also 
acceptable.
9
WARNING
When connected to a 4 or 5-wire, 120/208-Volt 3-
phase power supply; the phase C conductor is not 
required for the operation of the appliance.
Four-wire Connection
Ungrounded Neutral
Connect the red oven wire to the red electrical supply 
wire (hot wire).
Connect the black oven wire to the black electrical 
supply wire (hot wire).
Connect the white neutral oven wire to the white 
neutral (not bare or green ground) electrical supply 
wire.
Connect the green ground oven wire to the bare or 
green ground electrical supply wire.
Model
Connection
Circuit 
Requirements
HMC80251UC
4 wire conduit 
cable
208 V, 
60 Hz
20 Amps
240 V, 
60 Hz
20 Amps
HMC80151UC
NEMA 5-20
120 V,  
60 Hz 
20 Amps
HMC87151UC
NEMA 5-20
120 V,  
60 Hz
20 Amps
SRZHUVXSSO\
MXQFWLRQER[
UHGZLUHV
JUHHQRUEDUH
JUHHQZLUH
8/OLVWHG
FDEOHIURP
ZKLWHZLUHV
EODFNZLUHV
ZLUH
FRQQHFWRU