Руководство По Проектированию для Wolf CE365TS

Скачать
Страница из 26
wolfappliance.com   
|
   5
WOLF E SERIES OVENS
RANGES / RANGETOPS
OVENS / W
ARMING DRA
WERS
OUTDOOR GRILLS
VENTILA
TION
COOKTOPS / COFFEE SYSTEMS
Planning Information
The 24" E series oven can be installed in a standard or flush 
inset application. If a cooktop is being installed above an 
oven, a minimum of 
1
/
4
"
 (6)
 is required between units. Loca-
tion of the electrical supply within the oven opening may 
require additional cabinet depth.
Finish the edges of the opening. They may be visible when 
the door is open.
For standard installations, face trim will overlap stiles and 
rails. Refer to the chart below.
For flush inset installations, a minimum 
1
/
4
"
 (6)
 reveal is 
required on all sides. To ensure consistent reveals, each 
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
MIN
24" E Series Oven
150 lb
 (68 kg)
TRIM OVERLAP
Top
1
/
4
"
 (6)
Bottom
0"
 (0)
Sides
11
/
16
"
 (17)
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and 
within the shaded area shown in the illustrations on the 
following pages. For ease of installation, the electrical 
supply for the oven can be placed in an adjacent cabinet 
within reach of the conduit.
Performance may be compromised if the electrical supply is 
less than 240 volts.
The 24" oven comes equipped with a standard NEMA 6-20P 
style plug. Refer to the illustration below for minimum power 
cord plug clearance.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
20 amp dedicated circuit
Receptacle
NEMA 6-20R grounding-type
Power Cord
6'
 (1.8 m)
3"
(76)
MINIMUM CORD
CLEARANCE
 
Power cord clearance.