11
 Electrical Requirements 
 Electrical Requirements
Check your local codes regarding this unit. 
This cooktop is supplied with a 3-wire, A.C. 
208V/120 volt or 120V/240 volt, 60 HZ 
electrical system. A white (neutral) is not 
needed for this unit. See next section for 
grounding instructions.
 It should be fused 
separately.
Refer to the specifi cations chart for kilowatt 
rating and recommended amperage. House 
wiring and fusing must comply with local 
codes. If no local codes are applicable, wire 
in accordance with the National Electrical 
Code, ANSI/NFPA 70-latest edition. 
WARNING
  
BURN HAZARD
 The use of cabinets for storage 
above the appliance may result 
in potential burn hazard. Combustible 
items may ignite, metallic items may 
become hot and cause burns. If a cabinet 
storage is to provided the risk can be 
reduced by installing a range hood that 
projects horizontally a minimum of 5" (12.7 
cm) beyond the bottom of the cabinets. 
Electrical Connection 
When making the wire connections, use 
the entire length of the conduit provided 
(4 feet). The conduit must not be cut. 
Connect the red and black leads from the 
unit conduit to the corresponding leads in 
the junction box. The bare ground wire in the 
conduit is connected to the unit frame. When 
connecting to a 3-conductor branch circuit, 
connect the bare ground connector lead of 
the unit to the branch circuit ground (bare 
wire or green in color).
WARNING
    The electrical power to the 
unit must be shut off while line 
connections are being made. 
Failure to do so could result in serious 
injury or death. 
WARNING
   
 FIRE AND ELECTRICAL 
SHOCK HAZARD
 DO NOT use an extension 
cord with this appliance. Such 
use may result in fi re, electrical 
shock, or other personal injury.
CAUTION
 Be sure the electric power is 
off from the breaker box to the 
junction box until the cooktop 
is installed and ready to operate. The 
junction box should be connected to a 
suitable ground.