Руководство По Проектированию для Dacor DYRTP366SLPH

Скачать
Страница из 4
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
DYRTP366, DYRTP486
Discovery
 
36” and 48” Wide
Slide-in Gas Rangetops
Document # PG04-007
Revised 08/15/14   Page 3/4
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITHOUT DOWNDRAFT VENT - TOP VIEW
INSTALLED RANGETOP - SIDE VIEW
Model No.
B - Cutout Width
D - Hole Offset
DYRTP366
36” (91.4 cm)
16 5/8” (42.2 cm)
DYRTP486
48” (121.9 cm)
20 13/16” (52.9 cm)
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
Non-combustible 
rear wall, rear of 
mounting platform
10” (25.4 cm) min. 
to combustible wall 
above countertop, 
both sides
Cabinet face 
below countertop 
overhang
Increase countertop and overhang  
additional 2 1/2” (6.4 cm) min. for 
combustible rear wall  above 
countertop
3/8” (1.3 cm) 
countertop overhang
Hole 1/2” dia. (1.3 cm), 
2 places, through platform
for hold down bolts 
Gas/electrical utility cut-out in right rear corner of 
mounting platform 8” W X 6” D (20.3 cm X 15.2 cm),
if gas and electrical are routed through bottom
1/2” (1.3 cm) 
countertop 
overhang
1” (2.5 cm) thick mounting platform min.
Countertop
Countertop
1/2” (1.3 cm) 
countertop 
overhang
2” (5.1 cm)
Counterop 
overhang
1” (2.5 cm) 
typical
1 3/8” 
(3.5 cm) 
max.
11 7/16” 
(29.1 cm)
24”
(63.5 cm)
min. 
cabinet 
depth
CL
D
D
B
CL
CL
CL
Gas connection and power cord may be 
routed through bottom or back of chassis
Gas and electrical connections at 
right rear section of chassis
Cabinet 
face
Installed control 
panel overhang 
1/3/8” (3.5 cm)
24” (61.0 cm)
Countertop
Mounting platform