Инструкции По Установке для Maytag MLE24PDAWW

Скачать
Страница из 44
10
10
INSTALLATION INSTRUCTIONS – GAS DRYER
Make Gas Connection
1.   Remove red cap from gas pipe.
2.   Connect gas supply to dryer. Use pipe-joint compound 
resistant to the action of L.P. gas for gas connections. If 
flexible metal tubing is used, be certain there are no kinks.
 
 If necessary for service, open the toe panel. Use a putty knife 
to press on the toe panel locks located at the upper corners 
of the toe panel. Pull downward on the toe panel to open.  
Toe panel is hinged at the bottom.
3.   Open the shut-off valve in the gas supply line. 
4.   Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leaks found.
Connect Vent
1.   Using a 4" (102 mm) clamp, connect vent to exhaust outlet  
on rear of dryer. If connecting to existing vent, make sure the 
vent is clean. The dryer vent must fit over the dryer exhaust 
outlet and inside the exhaust hood. Make sure the vent is 
secured to exhaust hood with a 4" (102 mm) clamp.
2.   Using two or more people, move dryer to desired installation 
location. Do not crush or kink vent. Make sure dryer is level.
3.  Check that there are no kinks in the flexible gas line.
Complete Installation
1.   With dryer in final position, place level on top of the dryer, first 
side to side; then front to back. If the dryer is not level, adjust 
the legs of the dryer up or down until the dryer is level.
2.   Using a TORX
®†
 T20 security driver, open the control panel 
and rest it on the bottom edge of the opening. 
3.   For added security between the upper dryer and the collar, 
insert the cotter pin through the connecting bolt.
4.   Close the control panel.
5.   Plug into a grounding 3-prong outlet.
6.   Check dryer operation. 
 
 Select a full heat cycle, let the dryer run for at least five 
minutes. Dryer will stop when time is used up.
 
 NOTE: DRYER DOOR MUST BE CLOSED FOR DRYER 
TO OPERATE. When door is opened, dryer stops, but time 
continues to count down. To restart dryer, close door and 
reselect cycle.
7.   If the burner does not ignite and you can feel no heat inside 
the dryer, shut off dryer for five minutes. Check that all supply 
valve controls are in “ON” position and that the electrical cord 
is plugged in. Repeat five-minute test.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
INSTALLATION INSTRUCTIONS – ELECTRIC DRYER
Make Electrical Connection
Power Supply Cord Method – U.S. Only
  This dryer is manufactured ready to install with a 3-wire 
electrical supply connection. The neutral ground conductor is 
permanently connected to the neutral conductor (white wire) 
within the dryer. If the dryer is installed with a 4-wire electrical 
supply connection, the neutral ground conductor must be 
removed from the external ground connector (green screw), 
and secured under the neutral terminal (center or white wire) 
of the terminal block. When the neutral ground conductor is 
secured under the neutral terminal (center or white wire) of the 
terminal block, the dryer cabinet is isolated from the neutral 
conductor.
† ® TORX is a registered trademark of Saturn Fasteners, Inc.