A. Spade terminals with upturned ends
B. Ring  terminals
C. Neutral (white or center)
D. 3/4" (19 mm) UL-listed strain relief
E. Neutral
A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Strain relief screw
E. Neutral (center wire)
F. Appliance neutral ground wire
A. Separate copper ground wire
B. External ground conductor screw
C. Appliance neutral ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Strain relief screw
G. Neutral (center wire)
G
F
E
Power Supply Cord,  
Three-wire electrical connection
:
B
A
E
F
D
C
Three-wire power supply cord must 
have three, No. 10 copper wires and 
match a three-wire receptacle of 
NEMA Type 10-30R.
E
C
D
This blade connected to 
this conductor. 
B
A
5.   Loosen or remove the center terminal 
block screw.
6.   Connect the neutral wire (white or center) 
of the power supply cord to the center 
terminal screw of the terminal block. 
Tighten screw.
7.   Connect the other wires to outer terminal 
block screws. Tighten screws.
8.   Tighten strain relief screws.
9.   Insert tab of the terminal block cover into 
slot of the dryer rear panel. Secure cover 
with hold-down screw.
D
A
C
B
5.   Remove the center terminal block screw.
6.   Remove the appliance neutral ground 
wire from the external ground conductor 
screw. Connect the appliance neutral 
ground wire and the neutral wire (white or 
center) of the power supply cord under 
the center terminal block screw. Tighten 
screw.
7.   Connect the other wires to outer terminal 
block screws. Tighten screws.
8.   Tighten strain relief screws.
9.   Insert tab of the terminal block cover into 
slot of the dryer rear panel. Secure cover 
with hold-down screw.
10.  After reattaching the terminal cover, 
connect a separate copper ground wire 
from the external ground conductor screw 
to an adequate ground.
If codes permit and a separate ground wire  
is used, it is recommended that a qualified 
electrician determine that the ground path  
is adequate.
Use this method where local codes permit  
connecting neutral ground wire to neutral wire:
Use this method where local codes do not permit 
connecting neutral ground wire to neutral wire: