Инструкции По Установке для Maytag MLE24PDAWW

Скачать
Страница из 44
14
14
A. 3/4" (19 mm) conduit connector
B. Neutral (white or center)
C.  10-gauge, 3 wire with ground 
wire in flexible metallic conduit
A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Neutral (center wire)
E. Appliance neutral ground wire
Shape 
ends of 
wires into  
a hook.
Strip 3
1
2
" (89 mm) of outer 
covering from end of cable. 
Strip insulation back 1"  
(25 mm). If using 3 wire 
cable with ground wire,  
cut green or bare wire  
even with outer covering.
Three wire with ground wire: green or bare 
wire cut short. Wire is not used. Dryer is 
grounded through neutral conductor.
To  
disconnect 
box
1” (25 mm) 
of wires 
stripped of 
insulation
3
1
2
" (89 mm)
5.   Loosen or remove the center terminal 
block screw.
6.   Place the hooked end of the neutral wire 
(white or center) of the direct wire cable 
under the center screw of the terminal 
block (hook facing right). Squeeze 
hooked end together. Tighten screw.
7.   Place the hooked ends of the other 
direct wire cable wires under the outer 
terminal block screws (hook facing right). 
Squeeze hooked ends together. Tighten 
screws.
8.   Insert tab of the terminal block cover into 
slot of the dryer rear panel. Secure cover 
with hold-down screw.
5.   Remove the center terminal block screw.
6.   Remove the appliance neutral ground wire 
from the external ground conductor screw. 
Connect the appliance neutral ground wire 
and the neutral wire (white or center) of the 
direct wire cable under the center terminal 
block screw. Tighten screw.
7.   Connect the other wires to outer terminal 
block screws. Tighten screws.
8.   Insert tab of the terminal block cover into 
slot of the dryer rear panel. Secure cover 
with hold-down screw.
9.   After reattaching the terminal cover, 
connect a separate copper ground wire 
from the external ground connector screw 
to an adequate ground.
If codes permit and a separate ground wire 
is used, it is recommended that a qualified 
electrician determine that the ground path  
is adequate.
Direct Wire,  
Three-wire electrical connection:
Use this method where local codes  
permit connecting neutral ground wire to  
neutral wire:
Use this method where local codes do 
not permit connecting neutral ground 
wire to neutral wire:
A
B
C
A
B
C
D
E
A. Separate copper ground wire
B. External ground conductor screw
C. Appliance neutral ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Neutral (center wire)
F
E
D
A
C
B