Electrical Requirements – Gas Dryer
IMPORTANT: The dryer must be electrically grounded in 
accordance with local codes and ordinances or, in the absence  
of local codes, with the National Electrical Code, ANSI/NFPA 70, 
latest edition. 
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association 
One Batterymarch Park, Quincy, MA 02269
n
   A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit  
is required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this dryer be provided.
Recommended Ground Method
The dryer, when installed, must be electrically grounded in 
accordance with local codes or, in the absence of local codes, 
with the National Electrical Code, ANSI/NFPA 70, latest edition.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of a malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be 
plugged into an appropriate outlet that is properly installed 
and grounded in accordance with all local codes and 
ordinances.
WARNING: 
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative or 
personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with the 
dryer: if it will not fit the outlet, have a proper outlet installed 
by a qualified electrician.
Product Dimensions
Back View
approx. 1" 
(25 mm)
23
3
4
(603 mm)
Door
Top dryer 
exhaust
Bottom 
dryer 
exhaust
41
1
2
(1054 mm)
76
3
8
(1940 mm)
13
1
2
(343 mm)
Side View
29" (737 mm)
37" 
(940 mm)
5" (127 mm)
10
1
4
(260 mm)
3
1
4
(83 mm)
Top dryer 
gas line
Bottom 
dryer 
gas line
5
1
2
(140 mm)
NOTE: Gas lines 
located 1
1
4
(32 mm) inward 
from adjacent 
side. 
Electric
41
1
/2" 
(1054 mm)
Gas
18
1
8
"  
(460 mm)
9
1
4
"  
(235 mm)