C L E A N I N G   A N D   C A R E
FAN
The fan will automatically start when heat rises from 
range surface units or burners and when convection, 
high mix, low mix or the broil settings are used. This 
protects  the  microwave  oven  from  excessive  tem-
perature rise. The fan will stay on until the temperature  
decreases.  It  cannot  be  turned  off  manually  during          
this time.
For other uses, select either high or low speed.
PRECAUTIONS FOR PROPER USE:
1.  DO NOT leave range unattended while using high 
temperatures. Automatic fan may start and provide 
excessive air to the surface units. This may cause 
spattering or boilover.
2.  Avoid burning food.
3.  Keep grease filters clean.
lIGHT
1.  To replace light bulbs, first disconnect power to the 
oven at the circuit breaker panel or by unplugging.
2.  To release cover remove the screw on the light cover. 
(See illustration.)
3.  Replace  bulbs  only  with  equivalent  watt  bulbs         
available from a Sharp Authorized Servicer or parts 
distributor. Bulbs are also available at most hardware 
stores  or  lighting  centers.  DO  NOT  USE A  BULB 
LARGER THAN 30 WATTS.
4.  Close light cover and secure with screw removed in 
step 2.
CAUTION: Light cover may become very hot. Do not 
touch glass when light is on. Do not use light for long 
time use such as a night light.
Light cover
Screw
Light bulbs
CHARCOAl FIlTER 
Charcoal Filter, Sharp Part Number RK-220 is used for 
Non-vented, recirculated installation. The filter should be 
changed every 6 to 12 months depending on use.
1.  Disconnect power to the oven at the circuit breaker 
panel or by unplugging. 
2.  Remove 3 screws that secure louver.
3.  Remove louver by inserting flat edge screwdriver 
over each tab pressing the tab down and moving 
louver away from unit.
4.  Pull the louver away from the oven.
5.  Remove  2  screws  that  secure  the  sensor  duct 
cover.
6.  Remove the sensor duct cover.
7.  Remove old charcoal filter (if one is installed).
8.  Slide new Charcoal Filter  into position on  the sup-
port tabs.
9.  Reattach  sensor  duct  cover  and  secure  with  2 
screws.
10. Push louver back into place and gently snap tabs 
into  place  by  hand  (engaging  both  the  bottom 
and top tabs) and replace the 3 screws to secure 
louver.
Sensor duct cover
Charcoal filter