Installing the Anti-Tip Bracket to the Wall
1.  Determine the suitability of wall mounting the anti-tip bracket. 
To use the wall mount option, the range front panel (excluding 
the bull nose) must not be more than 27 inches (68.6 cm) 
from the wall, and the bracket screws must be able to thread 
into the back wall’s interal base plate (see Inside the Back 
Wall).
2.  The notches on the sides of the bracket indicate the minimum 
required height of the base plate and that any floor covering 
is not too thick for proper screw thread engagement.
Determine if the Base Plate is High Enough: 
The base plate is located on the floor, behind the wall. It will 
anchor the anti-tip bracket (see Inside the Back Wall).
Find the range’s center line and front panel according to 
the diagram below and the final installation cabinet / cutout 
dimensions.
1.  Find and mark the position of the anti-tip bracket, based on 
the diagram below. 
2.  Push the bracket up against the wall and into position.
3.  Determine if the base plate behind the wall (see Inside the 
Back Wall) is tall enough to grab the screws. 
• 
Using a pencil, mark a dot next to the notches on both sides 
of the bracket. Drill just deep enough to see if the bit contacts 
the base plate. 
• 
When the drill bit contacts the base plate, you will know 
screws in the anti-tip bracket will also contact the base plate. 
This setup is successful.
• 
If the drill bit does not contact the base plate, the wall 
mounting method should not be used. The floor mounting 
method is more suitable, or the wall must be modified so that 
the base plate can be accessed or anchors can be used.
CL
CL
Installing the Anti-Tip Bracket to the Wall
SCREW SIZE TABLE
Sub-Floor Type/Floor 
Covering Thickness
Screw Size
Concrete or wood sub-
floor, no floor covering
#8 x 1 *
Concrete or wood sub-
floor, floor covering up to 
1/4” thick
#8 x 1 *
Concrete or wood sub-
floor, floor covering over 
1/4” and up to 1/2” thick
#8 x 1 1/4 *
Wood sub-floor, floor 
covering over 1/2” and up 
to 1 3/16” thick
#12 x 1 3/4 *
Concrete under floor 
covering over 1/2” thick
Must be purchased separately **
Wood sub-floor, floor 
covering over 1 3/16” thick
Must be purchased separately **
* Included with range
** Determine required depth based on information in Step 3 and 
purchase from local hardware store.
Range front panel
Wall
Anti-tip
bracket
Base 
plate
Drywall
Notch
Wall Mounted Anti-Tip Bracket (Top View)
11 7/8”
Installation Instructions
Inside the Back Wall (Side View)