Инструкции По Установке для Dacor RGC365BNGH

Скачать
Страница из 16
4
Cabinet Layout
 WARNING
To reduce the risk of personal injury caused by 
reaching over a hot appliance, avoid locating cabinet 
storage space directly above the cooktop.
To reduce the risk of fire hazard, observe all specified 
clearances.
The back edge of the cooktop must be located a 
minimum of 2 ½” (64 mm) from any combustible 
backsplash material. Special cabinet and countertop 
dimensions may be required.
Follow the countertop manufacturer’s instructions 
regarding the minimum corner radius, use of heat 
reflective tape, reinforcement of corners, etc.
The cooktop is designed for a 24” (610 mm) minimum 
base cabinet depth.
Carefully check the location where the cooktop will be 
installed. For best performance, the cooktop should be 
placed away from drafts that may be caused by doors, 
windows and heating and air conditioning outlets. 
Plan the installation so that all clearances shown below 
are met or exceeded. Dimensions shown provide 
minimum and maximum clearances, unless otherwise 
noted.
Model
A: Minimum
A: Recommended
RGC304
30” (762 mm)
36” (914 mm)
RGC365
36” (914 mm)
42” (1067 mm)
Installation Specifications
Allow a minimum ¼” (6 mm) clearance between the 
bottom of the cooktop chassis and all combustible sur-
faces, including the upper edge of a drawer installed 
below the cooktop.
Model
B: Minimum
RGC304
29” (737 mm)
RGC365
35 ¼” (895 mm)
The gas supply piping, gas shut-off valve and the elec-
trical outlet must be located so they do not interfere 
with the cooktop when it is installed. If installing another 
appliance in the cabinet below, allow for the routing of 
gas and electrical service behind it.
The installation must allow for the following:
Access to the gas shut-off valve and regulator when 
the unit is installed. 
Access to the electrical outlet when the cooktop is in 
place. The 40” (1016 mm) power cord must be able to 
reach the electrical outlet.
Access to the underside of the cooktop for service and 
inspection purposes.
Clearance inside the cabinet to allow for proper hold 
down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed 
shelf should not be installed below the cooktop.
1/4” (6 mm)
Mimimum clearance
to combustible
surfaces
Under Cabinet Clearances
13" Max.
(330 mm)
A
3 1/8" Min.
(79 mm)
18" Min.
(457 mm)
30" Min.
(762 mm)
Clearances to Combustibles
All tolerances +1/16” -0 (+1.6 mm, 0) 
unless otherwise noted.