Инструкции Для Сборки для Hansgrohe 18115001

Скачать
Страница из 12
3
Installation
Remove the caps from the plaster shields on the rough 
valve (1).  
Cut the plaster shields so that they extend 1/16” outside 
the surface of the finished wall (2).  
Remove the plug from the spout outlet using a 17 mm 
socket wrench (1).
Install the valve slip coupling on one of the the valves (2).  
Mark a point on the slip coupling 3/16” from the surface 
of the finished wall.  Cut the slip coupling at that point 
(3).  
Install the spindle extension (1).  
Mark a point on the spindle extension 9/16” from the 
surface of the finished wall.  Cut the spindle extension at 
that point (2).
Seal the wall around the plaster 
shields with waterproof sealant.
Failure to seal the wall can lead to 
possible water damage.
2
1
3