Техническое Описание для Best PIK

Скачать
Страница из 4
PIK MOUNTING
S
IZE
 
OF
 
THE
 
CUT
-
OUT
NOTE: The 3 1/2’’ notch must be cut only if the WCPI
             optional wall control will be installed.
HH0040A
1 1/2”
HD0093A
17 1/16''
16 3/8''
32 1/2'' or 44 1/2''
3 1/2''
2 1/4'' min.
NOTE: If optional L series liner is used, refer to installation
             instructions for size and location of the cut-out.
Suggested Custom Hood Internal Framework
HL0065
- 3 -
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
L3336S, L3342S, L4548S
L4554S or L4560S
Custom Hood Liner (optional)
Model 415
7” Round
adjustable elbow
(optional)
8” Round 
adjustable elbow
(optional)
Model 412 
transition
(3¼” x 10” to 7”)
Adapter and damper 3¼’’ x 10’’
(supplied with P5 and P8 blowers)
Adapter and damper 3¼’’ x 14’’
(supplied with P8 blower)
Model P5 
single-blower
(500 cfm)
PIK33 OR PIK45
INSERT
- PIK33 
AND
PIK45
INSERT SYSTEM
-
INTERIOR BLOWERS
Flow deviator 
(supplied with P5 and P8 blowers)
Model 647
(7” Round
wall cap)
Model 634 or 644
(roof cap)
Model 643
(8” Round
wall cap)
8” Round
standard
duct
Model 407
(7” Round x 24’’
section)
7” Round
metal flexible
duct (optional)
8” Round 
metal flexible duct
(optional)
Model 413 
transition
(3¼” x 10” to 8”)
Model 459 
transition
(3¼” x 14” to 8”)
Model P8
dual-blower (900 cfm)
NOTE: The dual blower P8 must be 
installed with 8’’ round duct. If it 
is impossible to connect the dual 
blower P8 to a 8’’ round duct, 
use a 7’’ round duct. In that 
case, the blower performance 
will be decreased by 25%.
Rough-in kit 
(supplied with P5 and P8 blowers)
ALP36, ALP42, 
ALP48, ALP54 or ALP60
Ambient light panel (optional)
WCPI
Wall control
(Optional)