Downdraft Ventilators
1.  The interior down-
draft blower system is
designed for use with
3-1/4" x 10" ductwork
(can be transitioned
to 6" round). Three
different discharge
directions are avail-
able with side-to-
side adjustment for
accurate alignment of
ductwork.
2.  For best performance:
Choose the ducting
option which allows
the shortest length
of ductwork and a
minimum number of
elbows and transi-
tions. Check location of floor joists, wall studs, electrical
wiring or plumbing for possible interference.
RIGHT
DISCHARGE
DOWN DISCHARGE
LEFT
DISCHARGE
PLAN THE DUCTWORK
Interior Blower Installation
Exterior or In-Line Blower Installation
EQUALS 8 FT. OF
STRAIGHT DUCT
6" ROUND
ELBOW
EQUALS 14 FT. OF
STRAIGHT DUCT
3.  The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has 
been taken into consideration. Do not include them in this 
calculation.
3-1/4" X 10" TO 6" RD.
TRANSITION
3-1/4" X 10"
90
O
ELBOW
EQUALS
2 FT. OF
STRAIGHT DUCT
1.  The interior down-
draft blower system is
designed for use with
3-1/4" x 14" ductwork
(can be transitioned
to 8" or 10" round).
Three different dis-
charge directions are
available with side-to-
side adjustment for
accurate alignment of
ductwork.
2.  For best performance:
Choose the ducting
option which allows
the shortest length
of ductwork and a
minimum number of
elbows and transi-
tions. Check location of floor joists, wall studs, electrical
wiring or plumbing for possible interference.
RIGHT
DISCHARGE
DOWN DISCHARGE
LEFT
DISCHARGE
EQUALS 11 FT. OF
STRAIGHT DUCT
8" ROUND ELBOW
EQUALS 19 FT. OF
STRAIGHT DUCT
3.  The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has 
been taken into consideration. Do not include them in this 
calculation.
3-1/4" X 14" TO 8" RD.
TRANSITION
3-1/4" X 14" 90
O
ELBOW
EQUALS
5 FT. OF
STRAIGHT
DUCT
Interior Blower Installation
Exterior or In-Line Blower Installation
TAKE MEASUREMENTS 
(CONTINUED)
SIDE VIEW
OF DOWNDRAFT
SIDE VIEW
OF DOWNDRAFT