88
Vario cooktops
V I 414 110
Stainless steel frame
Width 38 cm
Width 38 cm
Installation accessories
V A 420 010
V A 420 010
Connection strip for combination with
other Vario appliances of the 400
series for surface installation
other Vario appliances of the 400
series for surface installation
V A 420 011
Connection strip for combination with
other Vario appliances of the 400
series for surface installation with
appliance cover/adjustment strip
other Vario appliances of the 400
series for surface installation with
appliance cover/adjustment strip
V A 420 000
Connection strip for combination with
other Vario appliances of the 400
series for flush installation
other Vario appliances of the 400
series for flush installation
V A 420 001
Connection strip for combination with
other Vario appliances of the 400
series for flush installation with
appliance cover/adjustment strip
other Vario appliances of the 400
series for flush installation with
appliance cover/adjustment strip
V A 440 010
Stainless steel appliance cover with
mounting strip
mounting strip
V A 450 400
Stainless steel adjustment strip 38 cm
Required accessory for combination of
several Vario appliances of the 400
series with at least one appliance cover
to compensate the appliance depth.
Required accessory for combination of
several Vario appliances of the 400
series with at least one appliance cover
to compensate the appliance depth.
Special accessories
W P 400 001
W P 400 001
Wok pan made of multiple-layer
material
With round bottom and handle,
ø 36 cm, 6 litres, height 10 cm.
material
With round bottom and handle,
ø 36 cm, 6 litres, height 10 cm.
W Z 400 001
Wok attachment for wok pan
Only for Vario induction wok.
Only for Vario induction wok.
Vario induction wok 400 series
V I 414
– 28 cm cooking zone with booster
function
– Ideal for the original wok pan with
round bottom, with wok ring
– Solid stainless steel control knob
– Precision crafting of 3 mm stainless
steel
– For surface installation with a
visible edge or for flush installation
– Can be combined perfectly with
other Vario appliances of the 400
series
series
Cooking zones
1 induction wok zone ø 18 cm (1,800 W,
with booster 2,500 W), which
automatically expands to ø 28 cm
(2,800 W, with booster
3,600 W).
with booster 2,500 W), which
automatically expands to ø 28 cm
(2,800 W, with booster
3,600 W).
Handling
Control knobs with illuminated ring,
cooking zone and output level
markings.
Electronic control in 12 output levels.
cooking zone and output level
markings.
Electronic control in 12 output levels.
Features
Cooking zone marking.
Booster function for each cooking
zone.
Pot detection with automatic activation
of the outer cooking zone.
Timer.
Booster function for each cooking
zone.
Pot detection with automatic activation
of the outer cooking zone.
Timer.
Safety
Residual heat indication.
Safety shut-off.
Safety shut-off.
Planning notes
Depending on the type of installation
(surface-mounted or flush-mounted,
with or without an appliance cover), the
specific location of the cut-out and the
knob positions may vary.
If installing with the appliance cover
VA 440 or adjustement strip VA 450
take into account the additional space
required for the depth.
If combining several appliances with at
least one appliance cover, the
adjustment strip VA 450 is required to
compensate for the depth of the
appliance without the appliance cover.
If combining several Vario appliances
of the 400 series, a connection strip
VA 420 must be placed between the
appliances. Depending on the type of
installation, the corresponding
connection strip must be provided.
In the cut-out, the installation system
requires the side edge to be at least
10 mm for surface installation and at
least 13 mm for flush installation.
Ensure a continuous cut surface of
90°.
The bearing capacity and stability, in
the case of thin worktops in particular,
must be supported using suitable
substructures. Take into account the
appliance weight and additional loads.
Additional instructions for flush installa-
tion:
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manu-
facturer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured.
Do not use discontinuous lining.
(surface-mounted or flush-mounted,
with or without an appliance cover), the
specific location of the cut-out and the
knob positions may vary.
If installing with the appliance cover
VA 440 or adjustement strip VA 450
take into account the additional space
required for the depth.
If combining several appliances with at
least one appliance cover, the
adjustment strip VA 450 is required to
compensate for the depth of the
appliance without the appliance cover.
If combining several Vario appliances
of the 400 series, a connection strip
VA 420 must be placed between the
appliances. Depending on the type of
installation, the corresponding
connection strip must be provided.
In the cut-out, the installation system
requires the side edge to be at least
10 mm for surface installation and at
least 13 mm for flush installation.
Ensure a continuous cut surface of
90°.
The bearing capacity and stability, in
the case of thin worktops in particular,
must be supported using suitable
substructures. Take into account the
appliance weight and additional loads.
Additional instructions for flush installa-
tion:
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manu-
facturer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured.
Do not use discontinuous lining.
The joint width may vary due to size
tolerances of the combinations and of
the worktop cut-out.
tolerances of the combinations and of
the worktop cut-out.
Please read additional planning notes
on page 116–123 .
on page 116–123 .
If installing several appliances in
individual cut-outs allow for a division
bar of minimum 50 mm between the
individual cut-outs.
Operates with magnetic (induction)
iron pots and pans only. For an optimal
heat distribution, the use of sandwich
bottom cookware is recommended.
Immersion depth depending on
installation situation 54/57 mm.
Built-in control panel to be integrated
in the bottom cabinet at drawer level.
Panel thickness 16 – 26 mm.
The drawing "Installation of the control
knob" must be observed if the panel is
more than 26 mm thick (there must be
a recess at the rear).
Appliance can be snapped into the
worktop from above.
Appliance weight: approx. 9 kg.
individual cut-outs allow for a division
bar of minimum 50 mm between the
individual cut-outs.
Operates with magnetic (induction)
iron pots and pans only. For an optimal
heat distribution, the use of sandwich
bottom cookware is recommended.
Immersion depth depending on
installation situation 54/57 mm.
Built-in control panel to be integrated
in the bottom cabinet at drawer level.
Panel thickness 16 – 26 mm.
The drawing "Installation of the control
knob" must be observed if the panel is
more than 26 mm thick (there must be
a recess at the rear).
Appliance can be snapped into the
worktop from above.
Appliance weight: approx. 9 kg.
Connection
Total connected load 3.6 kW.
Connecting cable 1.5 m without plug.
Connecting cable 1.5 m without plug.