INSTALLATION (cont.)
Plugging in the Unit
1. Check the prongs and surface of the power cord plug for dust/dirt. If dust and/ 
or dirt are present, wipe off with a clean, dry cloth.
2. Check the power cord, plug and prongs for damage or excess play. If any 
damage or excess play is found, contact your MovinCool dealer for 
replacement.
WARNING: 
• If the power cord or plug is damaged, replacement must be 
performed by qualified electrical personnel.
• Do not connect or disconnect the power cord or attempt to operate 
buttons with wet hands. This could result in electrical shock.
• Because of potential safety hazards under a certain condition, we 
strongly recommend against the use of an extension cord. However, 
if you still elect to use an extension cord, it is absolutely necessary 
that it is a UL listed, 3-wire grounding type appliance extension cord, 
having a 3-blade and a 3-slot receptacle that plugs into the 
appliance. The marked rating of the extension cord should be the 
following rating or equivalent.
3. Check the power supply outlet rating and fuse size to match with table below.
CAUTION: The power source should be a dedicated single outlet 
circuit with UL recognized short-circuit and ground fault protective 
breaker. Do not share the power supply outlet with any other 
instrument or equipment. The minimum power supply rating and 
the recommended fuse size are listed above.
Note:
• Make sure the power supply outlet is free of dirt, dust, oil, water, or any other 
foreign matter.
• The Climate Pro 18 is equipped with UL recognized LCDI cord and NEMA plug 
configuration (5-20). The appropriate outlet must be used for this plug type.
Model
Rating of Extenstion Cord
Climate Pro 18
120 V, 20 A
Model
Minimum Power Supply Rating
Recommended Fuse Size
Climate Pro 18
115 V, 1 Phase, 60 Hz, 20 A
20 A maximum