Инструкция С Настройками для XO XOMA06

Скачать
Страница из 4
Makeup Air System (XOMA)
Install and Dimensions Sheet – RESIDENTIAL USE ONLY
ventilation
FOR PLANNING PURPOSES ONLY.  PLEASE REFER TO INSTALL GUIDE FOR DETAILED INSTRUCTIONS
.
XOMA Switch Assembly and Collar Specifications:
Unit Specifications
Weight: 1.5 lbs, 16 AWG x 2,
10A,  125VAC.  Refer to safety 
instructions prior to installation
.
2”
6”
3 ‐1/4”
XOMA Motorized Fresh Air Damper Specifications:
f
Unit Specifications
Weight: 3 lbs.
0.25 amps, 24 VAC, 60 HZ, 7 watts.  
Shipped in normally closed position.
8”
2
¾”
2
5/8”
¾”
Diameter of XOMA 
Motorized Fresh Air 
Damper available 
in 6”, 8” sizes.
2
¾”
24V low voltage wiring must be run at time of 
rough‐in. (not included by manufacturer)
The replenishment or 
make‐up air must be 
drawn from outside of the 
home
XOMA Fresh Air Damper  in 
normally closed position
3’
Outside fresh air inlet must be 
installed on the exterior of the 
house a minimum distance of 
10ft from combustion vents and 
other exhaust openings.  Locate 
the fresh air inlet away from any 
outside motor, generator, pump, 
BBQ grill, hearth/fire pit, 
XOMA Fresh Air Damper needs to be 
located a minimum of 3ft from 
kitchen exhaust hood.
During operation of the kitchen 
exhaust, the motorized damper will 
open to allow fresh outside air to 
enter the home.  When the exhaust 
24V  Plug‐in 
Transformer: 
Input : 120VAC, 
60 HZ, .23A
Output : 24VAC, 
20VA
XOMA Switch Assembly  
installed in rigid ducting 
above ventilation hood
g
p
chemical storage area, or any 
potentially hazardous exposure 
area.
system is not in use the motorized 
damper will close and no longer allow 
outside air to enter.
For general comfort and aesthetics, 
the XOMA Fresh Air Damper intake 
needs to be located in an area that 
does not ventilate directly on or into 
kitchen preparatory or dining areas.
For maximum performance, the XOMA Switch 
Assembly needs to be installed directly above 
the kitchen exhaust.
Installation must completed by a certified installation expert or HVAC professional and must follow all local, state, and federal HVAC codes, 
laws, standards, and regulations.
2