Инструкции По Обслуживанию для Premium PIA18064A

Скачать
Страница из 44
Service manual 
30 
 
 
If compressor turns off for continuously 4 times due to current protection in 5 minutes from Compressor 
On, the unit stops and LED displays failure information and can’t returns to  normal operation 
automatically. 
 
8.4 
  Fan-only mode 
Fan speed is high/mid/low/ Auto 
 
8.5 
  Cooling mode 
The 4-way valve is closed at cooling mode.   
The action of the compressor and the outdoor fan:(T=indoor temperature) 
0
T-Ts
Room temp. up
Room temp. down
1
Compressor on 
outdoor fan on
Compressor off 
outdoor fan off
 
Auto fan at cooling mode: