INSTALLATION INSTRUCTIONS
EXTERIOR-MOUNTED VENT MOTOR
CAUTION: To reduce the risk of fire and electrical shock, install 
the downdraft only with remote blower systems that are sold by 
Whirlpool Corporation. Model numbers UXI0600DYS (600 cfm) 
and UXI01200DYS (1200 cfm).
NOTE: Exterior mounted vent motor installations require an 
approved in-line blower motor system. Model numbers 
UXI0600DYS (600 cfm) and UXI1200DYS (1200 cfm) are available 
from your dealer or authorized parts supplier. See “Blower motor 
system” in the “Accessories” section.
Venting Methods
Determine which venting method is best for your application. 
Vent system can terminate through the wall or roof. A wall cap or 
roof cap is required.
NOTES: 
Venting through a concrete slab is not recommended.
The in-line blower motor system must be placed in an 
enclosed area and can be located in a utility room, basement, 
crawl space or attic. Observe all governing codes and 
ordinances. 
10" (25.4 cm) round vent duct is required for connections to 
the retractable downdraft vent system outlet cover and the 
in-line blower motor inlet and outlet covers. 10" (25.4 cm) 
round vent duct is recommended for the retractable 
downdraft vent system with in-line blower motor system. 
Transitioning to different size ducting will reduce the 
efficiency of the retractable downdraft vent system.
Built-In Cabinet Locations
Calculating Vent System Length
It is recommended that you use round vent instead of rectangular 
vent, especially if elbows are required. If rectangular vent is 
required, it should be transitioned to 10" (25.4 cm) round vent as 
soon as possible.
Maximum Length of Vent System
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.
The maximum equivalent vent lengths of 10" (25.4 cm) round 
vents - 60 ft (18.3 m).
NOTE: The exterior-mounted vent motor requires a separate 
wiring cable that should be installed at the same time the vent 
work is installed.
Island location - front vent
Island location - rear vent
          To attic 
    installed in-line 
blower motor system
  To basement, crawlspace 
    or utility room installed 
in-line blower motor system
  To basement, crawlspace 
    or utility room installed 
in-line blower motor system
          To attic 
    installed in-line 
blower motor system
Vent
Length
10" (25.4 cm) round
60 ft (18.3 m)
Vent Piece
10" (25.4 cm) Round
45° elbow
2.5 ft
(0.8 m) 
90° elbow
5.0 ft
(1.5 m)
2 - 90° elbows
= 10.0 ft (3 m)
10 ft (3 m) straight
= 10.0 ft (3 m)
Length of 10" (25.4 cm) 
system
= 20 ft (6 m)
          To attic 
    installed in-line 
blower motor system
  To basement, crawlspace 
    or utility room installed 
in-line blower motor system