Complete Preparation
1. Determine and make all necessary cuts for the vent system.
IMPORTANT: When cutting or drilling into the floor, ceiling or 
wall, do not damage electrical wiring or other hidden utilities.
2. Determine the location where the 
¹⁄₂" (1.3 cm) wiring conduit 
will be routed through the floor, ceiling or wall between the in-
line blower and the downdraft vent.
3. Drill a 1
¹⁄₄" (3.2 cm) hole at this location.
4. Locate the electrical terminal boxes in the in-line blower 
housing and downdraft vent. Remove the terminal box covers 
and set the covers and screws aside.
5. Remove the electrical knockout from the in-line blower 
housing and downdraft vent to prepare for the installation of 
the UL listed or CSA approved 
¹⁄₂" (1.3 cm) wiring conduit and 
conduit connector. 
6. With the downdraft vent mounted, run the 
¹⁄₂" (1.3 cm) wiring 
conduit between the in-line blower motor housing and the 
downdraft vent. Pull enough 
¹⁄₂" (1.3 cm) wiring conduit to 
allow for easy connection to the terminal boxes in the in-line 
blower housing and downdraft vent. 
7. Run the six 18 AWG wires through the 
¹⁄₂" (1.3 cm) wiring 
conduit and conduit connectors and into the terminal boxes 
on the in-line blower housing and downdraft vent. Leave 
enough wire length in each terminal box to make the wiring 
connections.
8. Install the conduit connectors and conduit to the in-line 
blower housing and downdraft vent electrical terminal boxes.
9. Connect the vent system to the downdraft vent and in-line 
blower system and seal all joints with clamps.
Make Electrical Connections for In-Line 
Blower Motor System
Electrical Connection Inside In-line Blower System
1. Disconnect power.
2. Connect the wires from the wiring conduit to the wires from 
the motor electrical plug cable inside the in-line blower 
housing terminal box.
3. Use UL listed wire connectors and connect the black wires 
(C) together.
4. Use UL listed wire connectors and connect the white wires 
(D) together.
5. Use UL listed wire connectors and connect the red wires (E) 
together.
6. Use UL listed wire connectors and connect the blue wires (F) 
together.
7. Use UL listed wire connectors and connect the gray wires (G) 
together.
A. Electrical terminal box
B. Electrical knockout
A
B
A. UL listed or CSA approved 
¹⁄₂
" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or yellow/green) 
and green/yellow wires
I. Motor electrical plug cable
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.