Использование И Уход для WineMate Split System Wine Cooling Units - 1000 Cu. Ft. Wine Cellar

Скачать
Страница из 16
                                                                                
- 5 -
Installation Instruction 
 
 
Federal law requires that WINEMATE split cooling systems be 
installed by an EPA certified refrigeration technician.
 
 
1. Location 
 
•  Place the condensing unit in a properly ventilated location. If it is not, heat 
exhausted by the condensing unit will build up and the cooling system will 
not operate properly.  
•  Leave minimum 3 feet clearance between the exhaust side and the wall. 
•  Leave minimum 1 foot clearance for the fresh air supply side. 
•  Condensing unit should be elevated to avoid possible flooding and shaded 
from direct sun. It should not be exposed to temperatures higher than 125 
°
F or lower than 20 
°
F.  
•  Air flow from the unit cooler should be unobstructed for at least 1 foot. 
 
2. Refrigeration Installation 
 
Model 
Liquid Line Diameter 
(inch), recommended 
 
Suction Line Diameter 
(inch), recommended 
 
VINO2500SSD 1/4 
3/8 
VINO4500SSD 1/4 
1/2 
VINO6500SSD 1/4 
5/8 
VINO8500SSD 3/8 
5/8 
 
WINEMATE split system is shipped as components and is ready for use only 
after a certified refrigeration technician has properly installed and tested the 
system. Proper installation is critical.  WINEMATE can only warrant the quality of 
the components. The installation and proper operation of the system must be 
warranted by the installer.