Reset Button
Use the reset button located underneath the trim ring on the mounting flange to access the following 
modes:
To access one of these modes:
1. Press and hold the reset button. The unit starts cycling through the modes; hold the button for four 
seconds to access (cycle through) each mode. The unit status indicator LED flashes the color for the 
current mode (refer to the table above).
2. When the color of the desired mode appears, release the button.
NOTES:
If there is no configuration activity for 15 minutes, the dome system will automatically exit the reset 
mode.
The LED is not lit during normal operation.
Figure 19. Location of Reset Button and LED
Mode 
Function 
Unit Status Indicator Light 
Configuration
Starts the reset LED 
selection sequence.
Flashes green.
Reboot 
Restarts the unit. 
Flashes green and red simultaneously when entering this 
mode. The LED then flashes green when mode is selected 
and during the reboot.
Reset 
Resets unit to factory 
default settings and 
then restarts unit. 
Flashes red when entering this mode. Flashes red when 
mode is selected, and then flashes green when dome 
system restarts. Dome system is off line during reset 
mode. 
Cancel Cancels 
any 
configuration or reset 
action. 
No light.
Status Indicator LED