3) Settings for TIMER PROGRAM are made as follows.
• Designate Monday to Friday as the days of operation
(SPECIAL DW). Then, in Program #1, set the action  (MODE)
to “A–   1” for 08:00 to 15:00 on the designated days(SPL).
• In Program #2, set the action to “B–   1” for 15:00 to 20:00 on
the designated days.
• In Program #3, set the action to “B–   1” for 08:00 to 17:00 on
Saturday.
• In Program #4, set the action to “B–   1” for 08:00 to 17:00 on
Sunday.
• In Program #5, set the action to “EJECT”  for Sunday’s start-
time of 00:00 to end-time of 05:00.
Upon completing the above settings, press the unit’s TIMER
REC button to initiate Timer operation.
■ 
Operation example 4
This is an operation example of a Timer setting that com-
bines NORMAL REC with Alarm Recording using MOTION
DETECTION.
System configuration
Settings are entered so that the backups are created every
Monday morning between 00:00 and 05:00. To facilitate
the exchange of the storage medium after the backup has
been completed, MODE is set to “EJECT”.
Cameras in SELECT REC MODE (A) are set to operate
from 08:00 to 15:00 on Monday through Friday. Set the
unit on POWER from 15:00 to 08:00 the next morning.
Cameras in SELECT REC MODE (B) are set to operate
from 08:00 to next day 08:00 on Saturday and Sunday.
The overall schedule is as shown in the following chart.
Monday
00 : 00
00 : 00
05 : 00
Saturday and Sunday
08 : 00
08 : 00
24 : 00
Monday to Friday
08 : 00
15 : 00
Archive
SELECT REC MODE (A)
24 : 00
POWER
POWER
00 : 00
SELECT REC MODE (B)
replace archive medium
SELECT REC MODE (B)
Settings
1) Enter the same settings for the camera operation set-
ting A as those for operation example 3 in the following: the
CAMERA TITLE setting (on the <MPX DISPLAY> menu),
DEFINE GROUP SETTING (on the <NORMAL REC SET-
TING> menu), and recording conditions. Set the power set-
ting that uses MOTION DETECTION as follows.
• Set IMAGE QUALITY to “HIGH”.
• Set MAX REC FIELDS to “1F”.
• Set A-REC DURATION to “5M”.
• Set RECORD ALARM to “ALL”.
• Set PRE A-REC to “MEDIUM”.
• On the <DEFINE ALARM GROUP> menu, set the cameras
Q
,
W
,
E
,
I
,
O
,
}
 and 
w
.
<DEFINE ALARM GROUP>
CH PRI FILD  CH PRI FILD
@Q  2  0.11   O    1  0.22
  W  1  0.22   P    -    
  E  1  0.22   {    -    
  R  -         }    1  0.22
  T  -         q    -     
  Y  -         w    1  0.22
  U  -         e    -       
  I  2  0.11   r    -    
2) Settings for MOTION DETECTION SETTING are made
as follows.
To make the M-DET SETTING, first turn the MOTION
DETECTION setting “ON” in the <INITIAL SET UP> menu.
• Using SELECTION CAMERA NO., set each of the following
camera numbers 
Q
W
E
I
O
}
 and 
w
 as follows.
• Set CH.MOTION DETECTION to “ON”.
• Set SET DETECTION MASK, SENSITIVITY, MOTION
THRESHOLD TEST MODE.
<MOTION>
@SELECTION CAMERA NO.  
1
 
 
 CH.MOTION DETECTION  ON
 SET DETECTION MASK
 SENSITIVITY        HIGH
 MOTION THRESHOLD      5
 TEST MODE           OFF 
3) Settings for TIMER PROGRAM are made as follows.
• Select “P1” for the setting “SELECTED PATTERN” in the
<TIMER PROGRAM> menu and select “ON” for the setting
“REC MODE (POWER)” in the <M-DET APPLICATION> menu.
<TIMER PROGRAM>
 SELECTED PATTERN
 DEFINE P1
 DEFINE P2
 DEFINE P3

<M-DET APPLICATION>
 REC MODE (A)        OFF
 REC MODE (B)        OFF
 REC MODE (C)        OFF
@REC MODE (POWER)     ON
P1
• Designate Monday to Friday as the days of operation
(SPECIAL DW). Then, in Program #1, set the action  (MODE)
to “A–   1” for 08:00 to 15:00 on the designated days(SPL).
• In Program #2, set the action to “POWER” for 15:00 to 08:00
the next morning.
• In Program #3, set the action to “POWER” for 08:00 to 08:00
the next morning.
• In Program #4, set the action to “POWER” for 08:00 to 08:00
the next morning.
• In Program #5, set the action to “EJECT”  for Sunday’s start-
time of 00:00 to end-time of 05:00.
Upon completing the above settings, press the unit’s TIMER