COM220 Telephone Modem 
in Setup’s PakBusPort [LoggerNet, Setup, PakBusPort (in the device 
map)] may limit the baud rate selected by the modems since it defaults to 
9600.  You can sometimes achieve a higher connection baud rate by 
raising the PaKBus Port’s maximum baud rate. 
11)  Can you attach a normal analog telephone to the line and make a call out?  
If not, contact your local telephone company.  If you can make a call out 
but the connection is poor or faint, contact your local telephone company.   
12)  Verify the COM220 is receiving 12 VDC.  If the COM220 is receiving 12 
VDC from a separate power supply instead of the datalogger, is the ground 
of the separate power supply connected to the datalogger’s ground? 
13)  Verify the datalogger is turned on. 
To comply with FCC rules and regulations, all repairs on the COM220 modem 
must be performed by Campbell Scientific, Inc. or an authorized agent of 
Campbell Scientific, Inc.  For assistance in installation, troubleshooting, or for 
repair, contact Campbell Scientific: 