Справочник Пользователя для Mitsubishi Electronics C64T
8. Spindle Parameters
8.1 Spindle Base Specifications Parameters
180
# Items
Details
Setting range
(Unit)
3066 spdiv6
Magnification
for time
constant
changeover
speed 6
for time
constant
changeover
speed 6
Set the acceleration/deceleration time constant
between the spindle synchronization multi-step
acceleration/deceleration changeover speed 6
(sptc6) to the spindle synchronization
multi-step acceleration/deceleration
changeover speed 7 (sptc7) as a magnification
in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
between the spindle synchronization multi-step
acceleration/deceleration changeover speed 6
(sptc6) to the spindle synchronization
multi-step acceleration/deceleration
changeover speed 7 (sptc7) as a magnification
in respect to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3067 spdiv7
Magnification
for time
constant
changeover
speed 7
for time
constant
changeover
speed 7
Set the acceleration/deceleration time constant
for the spindle synchronization multi-step
acceleration/deceleration changeover speed 7
(sptc7) and higher as a magnification in respect
to the spindle synchronization
acceleration/deceleration time constant (spt).
for the spindle synchronization multi-step
acceleration/deceleration changeover speed 7
(sptc7) and higher as a magnification in respect
to the spindle synchronization
acceleration/deceleration time constant (spt).
0 to 127
3068 symtm1 Phase
synchroniza-
tion start
confirmation
time
tion start
confirmation
time
Set the time to confirm that synchronization is
attained before phase synchronization control
is started.
When "0" is set, the time will be 2 seconds.
When "100" or less is set, the time will be
100ms.
attained before phase synchronization control
is started.
When "0" is set, the time will be 2 seconds.
When "100" or less is set, the time will be
100ms.
0 to 9999 (ms)
3069 symtm2 Phase
synchroniza-
tion end
confirmation
time
tion end
confirmation
time
Set the time to wait for phase synchronization
control to end as the time for the rotation speed
to reach the attainment range.
When "0" is set, the time will be 2 seconds.
When "100" or less is set, the time will be
100ms.
control to end as the time for the rotation speed
to reach the attainment range.
When "0" is set, the time will be 2 seconds.
When "100" or less is set, the time will be
100ms.
0 to 9999 (ms)
3070 syprt
Phase
synchroniza-
tion speed
synchroniza-
tion speed
Set the fluctuation amount to change the
synchronous spindle rotation speed during
phase synchronization control as the command
speed and rate.
When "0" is set, the amount will be 100%.
synchronous spindle rotation speed during
phase synchronization control as the command
speed and rate.
When "0" is set, the amount will be 100%.
0 to 100 (%)
3071
(Not
used.)
3072
(Not
used.)