Справочник Пользователя для Mitsubishi Electronics C64T
8. Spindle Parameters
8.2 MDS-B-SPJ2
183
No. Items
Details
Setting
range
Standard
setting
3233
(PR)
SP033 SFNC1 Spindle
function 1
Set the spindle function 1 in bit units.
0000 to
FFFF
HEX setting
FFFF
HEX setting
0000
3234
(PR)
SP034 SFNC2 Spindle
function 2
Set the spindle function 2 in bit units.
(Note1) To validate bit3(mkc2), NC side needs to
prepare.
(Note1) Always turn the bit2 at the same time to use
bit3.
0000 to
FFFF
HEX setting
FFFF
HEX setting
0000
F E D
C
B A 9 8
poff
hzs
ront
7 6 5 4 3 2 1 0
sftk
dflt 1a2m
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
1a2m
1 amplifier
2 motor function: Invalid
2 motor function: Invalid
1 amplifier
2 motor function: Valid
2 motor function: Valid
1
dflt
Default motor: Main
Default motor: Sub
2
sftk
SF-TK card invalid
SF-TK card valid
3
4
5
6
7
8
9
A
B
C
ront
D
E
hzs
F
poff
This is a fixed control bit.
F E D
C
B A 9 8
7 6 5 4 3 2 1 0
mts1
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
mts1
Special motor constant
invalid
invalid
Special motor constant
setting valid
setting valid
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F