Справочник Пользователя для Mitsubishi Electronics C64T

Скачать
Страница из 317
11.  Macro List 
 
 
 
283 
11.  Macro List 
# Item 
Details 
Setting range (unit) 
7001 
to 
7091 
M [01] 
    to 
M [10] 
<Code> 
Set the M code used for calling out the macro with the M 
command. 
This is valid when "#1195 Mmac" is set to 1. 
1 to 9999 
7002 
to 
7092 
 <Type> 
Set the macro call out type. 
 
 
 
 
 
0 to 3 
7003 
to 
7093 
 <Program 
No.> 
Set the No. of the program to be called out. 
1 to 99999999 
 
M2mac 
Set the type and program No. for when calling out the macro with the 2nd 
miscellaneous command.  The macro will be called out with the "#1170 M2name" 
address command when "#1198 M2mac" is set to 1. 
7102  
<Type> 
Same as the M call macro. 
0 to 3 
7103  
<Program 
No.> 
Same as the M call macro. 
0 to 99999999 
7201 
to 
7291 
G [01] 
    to 
G [10] 
<Code> 
Set the G code to be used when calling the macro with a G 
command. Do not set a G code used in the system. 
1 to 255 
7202 
to 
7292 
 <Type> 
Same as the M call macro. 
0 to 3 
7203 
to 
7293 
 <Program 
No.> 
Same as the M call macro. 
1 to 99999999 
 
Smac 
Set the type and program No. for when calling the macro with an S command. 
This is valid when "#1196 Smac" is set to 1.  
7302  
<Type> 
Same as the M call macro. 
0 to 3 
7303  
<Program 
No.> 
Same as the M call macro. 
1 to 99999999 
 
Tmac 
Set the type and program No. for when calling the macro with a T command. 
This is valid when "#1197 Tmac" is set to 1. 
7312  
<Type> 
Same as the M call macro. 
0 to 3 
7313  
<Program 
No.> 
Same as the M call macro. 
0 to 99999999 
27000 Nmac 
Not 
used. 
27001 
to 
27071 
N [0] 
    to 
N [08] 
<Code> 
Not used. 
27002 
to 
27072 
 <Program 
No.> 
Not used. 
M98 P
∆∆∆∆; and equivalent value call 
G65 P
∆∆∆∆; and equivalent value call 
G66 P
∆∆∆∆; and equivalent value call 
G66.1 P
∆∆∆∆; and equivalent value call 
others 
M98 P
∆∆∆∆; and equivalent value call