12 - 39                                                                                                                                                       12 - 39 
MELSOFT
12. USEFUL FUNCTIONS 
 
DISPLAY/SETTING DATA
 
 
Item Description 
"Start" button 
Click this button to request the AD75 to start trace. 
If the trigger condition is "Unconditional", trace starts. 
If the trigger condition is other than "Unconditional", trace starts actually when the trigger 
condition holds. 
"Stop" button 
Click this button to stop trace and show the trace results. 
If the stop type is Buffer full, Error stop or Trace point, clicking the "Stop" button stops trace 
and shows the trace results available at that point. 
"Expanded" button 
Click this button to expand the track data. 
"Reduction" button 
Click this button to reduce the track data. 
Track data 
Shows the trace results. 
The X and Y axes indicate the respective addresses (travel distances) of the axis numbers 
set in trace condition setting. 
(When #1-2 is selected as the axis number to be traced, the X axis is Axis #1 and the Y axis 
is Axis #2.) 
Clicking 
 beneath the display or 
 on 
the right of the display moves the center of the display. 
Note that the center line does not move. 
Clicking 
 Center aligns the X-Y axis coordinates of 0 with the center of the screen.
Max 
Min 
Show the maximum and minimum values during tracing of each data. 
Time 
Shows the tracing time. 

Shows the coordinates where the displayed track data is moved with  
 , 
 
Data 1 
Data 2 
Shows the axes and data types set in the Trace condition dialog box. 
"Trace cond." button 
Click this button to display the Trace condition dialog box. 
 
HELPFUL OPERATION
 
 
Clicking the [Project] 
→ [Export file] → [File writing of trace data] menu saves the 
trace data and trace conditions. 
To read the trace data file, perform the following operation. 
1. Using Change AD75 model (refer to Section 12.1.2), choose the same model as 
the one at the time of write. 
2. Display the tracks display main screen. 
3. Click the [Project] 
→ [Import file] → [File reading of trace data] menu. 
4. Click the "OK" button in the on-screen trace data overwrite confirmation dialog 
box. 
5. Choose the file location and file name in the file opening dialog box and click the 
"Open" button to show the saved track data and trace conditions. 
 
 
 
 
   
The tracks display file cannot be read during wavy display.