Справочник Пользователя для Mitsubishi Electronics AD75P1/P2/P3

Скачать
Страница из 212
 
 
 
11 - 7                                                                                                                                                       11 - 7 
MELSOFT
11. POSITIONING DEBUGGING 
 
DISPLAY/SETTING SCREEN
 
 
[Start history monitor] 
[Start with error history monitor] 
 
 
 
DISPLAY/SETTING DATA
 
 
Item Description 
No. 
Represents the order of starts since power-on for the start history. 
Represents the order of starts after error occurrence for the error-time start history. 
If there are more than 16 starts, the older ones are deleted. 
For the error-time start history, its data is overwritten every time an error occurs. 
Axis 
Indicates the axis started. 
Buffer memory address: 462 to 622 
Start 
Indicates the start command destination. 
The command destination is the programmable controller CPU, peripheral device or external 
start. 
Buffer memory address: 462 to 622 
Mode 
Indicates the type of operation started. 
The positioning data No. is displayed for operation which uses the positioning data. 
Buffer memory address: 462 to 622 
Time 
Indicates the error/warning occurrence time in 100ms increments in relation to the time set to 
the AD75 in the sequence program. 
Buffer memory address: 462 to 622 
Result 
Shows OK for a normal start. 
Shows the error code when an error occurs. 
The error code can be confirmed in [Help]. 
Buffer memory address: 462 to 622