12. USEFUL FUNCTIONS 
 
DISPLAY/SETTING DATA
 
 
Item Description 
Trace 
Set the trace intervals within the range 1 to 256. 
Trigger 
Choose the actual trace starting condition. 
• Unconditional 
Trace starts at the start request of the peripheral device. 
• Busy ON 
Trace starts actually when the started signal (X1/X2/X3) turns on after the start request 
from the peripheral device. 
• PC trigger ON 
Trace starts actually when 1 is written to the buffer memory address 5050 of the AD75 
under the control of the sequence program after the start request from the peripheral 
device. 
Trace stop 
Choose the trace stopping condition. 
• Buffer full 
Trace stops when the trace data area becomes full. 
• Endless 
Trace stops at the stop request of the peripheral device. 
• Error stop 
Trace stops when an error occurs. 
• Trace point 
Trace stops when the number of trace points reaches the specified value. 
Data 1 
Data 2 
Represents the trace data No. 
When AD75P#-S3 or AJ65BT-D75P2-S3 is selected in Change AD75 model, only data 1 
may be traced. 
Axis No. 
Choose the axis combination whose data will be traced. 
In the track data of the trace results, the first axis number indicates the X axis and the second 
the Y axis. 
Data 
Choose the data type to be traced. 
• Pos. inst 
Feed address-based track data given from the AD75 to the servo amplifier. 
• Real value 
Track data based on the actual address of the AD75M. 
When AD75P#-S3 or AJ65BT-D75P2-S3 is selected in Change AD75 model, the traceable 
data is the speed command only. 
"OK" button 
Click this button to close the Trace condition dialog box and display the axis numbers and 
data types on the tracks display main screen.