Справочник Пользователя для Mitsubishi Electronics QD75P1

Скачать
Страница из 860
 
 
 
5 - 8 
MELSEC-Q
5      DATA USED FOR POSITIONING CONTROL 
 
5.1.4 Setting items for positioning data 
Positioning data must be set for carrying out any "major positioning control". The table 
below lists the items to be set for producing the positioning data. 
One to 600 positioning data items can be set for each axis. 
For details of the major positioning controls, refer to CHAPTER 9 "MAJOR 
POSITIONING CONTROL". For details of the individual setting items, refer to Section 
5.3 "List of positioning data". 
 
Major positioning control
 
 
 
 
 
 
 
 
 
Positioning data 
Position control 
 
 
 
Other control
 
1-
axi
s l
ine
ar
 c
ont
rol
 
2/
3/
4-
axi
s l
ine
ar
 
in
te
rp
ol
at
io
n co
nt
ro
1-
axi
s fi
xe
d-
fe
ed
 co
nt
rol
 
2/
3/
4-
axi
s fi
xe
d-
fe
ed
 co
nt
rol
 
2-
axi
s ci
rc
ul
ar
 in
te
rpol
ati
on 
co
nt
ro
to
 4 axi
sp
ee
d co
nt
ro
S
peed
-p
os
iti
on
 sw
itch
in
co
nt
ro
P
os
iti
on
-s
pee
d s
w
itch
in
co
nt
ro
N
O
P
 in
st
ru
ct
ion 
C
urre
nt
 va
lu
e ch
ang
ing 
JU
MP
 in
st
ru
ct
io
LO
OP
 
LE
N
D
 
 Da.1  
Operation 
pattern 
Independent 
positioning 
control 
 
 
 
 
 
 
– 
 
– – 
– 
Continuous 
positioning 
control 
 
 
 
 
 
 
– 
 
– – 
– 
Continuous path 
control 
 
 
 
 
 
 
– 
 
– – 
– 
 Da.2   Control system 
Linear 1 
Linear 2 
Linear 3 
Linear 4 
 
Fixed- 
feed 1 
Fixed- 
feed 2 
Fixed- 
feed 3 
Fixed- 
feed 4 
Circular 
sub 
Circular 
right 
Circular 
left 
 
Forward 
run speed 1
Reverse run 
speed 1 
Forward 
run speed 2
Reverse run 
speed 2 
Forward 
run speed 3
Reverse run 
speed 3 
Forward 
run speed 4
Reverse run 
speed 4 
Forward 
run 
speed/
position
Reverse 
run 
speed/
position
Forward 
run 
position/
speed
Reverse 
run 
position/
speed
NOP 
instruction
Current 
value 
changing 
JUMP 
instruction 
LOOP LEND
 Da.3   Acceleration time No. 
 
 
 
 
 
 
– – – – 
– 
 Da.4   Deceleration time No. 
 
 
 
 
 
 
– – – – 
– 
 Da.5  
Axis to be 
interpolated 
 : 2 axes 
  –  : 1/3/4 axes
– – –  –  – –  –  – – – 
– 
 Da.6  
Positioning address/ 
movement amount 
 
 
 
– 
 
 
– 
New 
address 
– – 
– 
 Da.7   Arc address 
– –   
– – 
– –  – – – 
– 
 Da.8   Command speed 
 
 
 
 
 
 
– 
– – – 
– 
 Da.9  
Dwell time   
(JUMP destination 
positioning data No.) 
 
 
 
 
 
 
– 
– 
JUMP 
destination 
positioning 
data No. 
– – 
 Da.10  
M code   
(JUMP condition data No.) 
 
 
 
 
 
 
– 
 
JUMP 
condition 
data No. 
No. of 
LOOP to 
LEND 
repetitions
– 
 
 
 : Always set 
 
 : Set as required  
 
  : Setting not possible 
  –  : Setting not required.     
(This is an irrelevant item, so the set value will be ignored. If the value is the default value or within the setting range, there is no problem.) 
 
  : Two control systems are available:    the absolute (ABS) system and incremental (INC) system.