5 - 108 
MELSEC-Q
5      DATA USED FOR POSITIONING CONTROL 
 
5.7.2 Axis control data 
Setting item 
Setting details 
 
 
 
 
 
 Cd.3   Positioning start No. 
 Set the positioning start No.   
(Only 1 to 600 for the Pre-reading start function. For details, refer to Section 
12.7.7 "Pre-reading start function".) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Cd.4   Positioning starting point No.
 
 Set a " starting point No." (1 to 50) if block start data is used for positioning.   
(Handled as "1" if the value of other than 1 to 50 is set.) 
 
 
 
 
 
 
 
 
 
 Cd.5   Axis error reset 
 Clears the axis error detection, axis error No., axis warning detection and axis 
warning No. 
 When the QD75 axis operation state is "Error", the error is cleared and the QD75 
is returned to the "Standing" state. 
 
 
 
 
 
 
 
 
 
 
 
 
 Cd.6   Restart command 
 When positioning is stopped for any reason (when axis operation state is 
"Stopped"), set "1" in   Cd.6 . Positioning will be carried out again from the 
stopped position to the end point of the stopped positioning data. 
 
 
 
 
 
 
 
 
 
 
 
 
 Cd.7   M code OFF request 
 The M code ON signal turns OFF.