Справочник Пользователя для Mitsubishi Electronics QD75P1

Скачать
Страница из 860
 
 
 
8 - 9 
MELSEC-Q
8   OPR CONTROL 
 
8.2.4 OPR method (2): Stopper method 1) 
The following shows an operation outline of the "stopper method 1)" OPR method.  
 Operation chart 
1) 
The machine OPR is started. 
(The machine begins the acceleration designated in "  Pr.51  OPR acceleration time selection", in the direction designated in 
"  Pr.44  OPR direction". It then moves at the "  Pr.46  OPR speed" when the acceleration is completed.) 
2) 
The machine begins decelerating when the near-point dog ON is detected. 
3) 
The machine decelerates to the "  Pr.47  Creep speed", and subsequently moves at that speed. 
(Torque limiting is required at this time.  If the torque is not limited, the servomotor may fail in step 4).) 
4) 
The machine presses against the stopper at the creep speed and stops. 
5) 
The pulse output from the QD75 will stop when the "  Pr.49  OPR dwell time" has elapsed after the near-point dog turns ON, outputting 
the "deviation counter clear output" to the drive unit. 
(A "deviation counter clear signal output time" is set in the  Pr.55 .) 
6) 
After a "deviation counter clear output" is output to the drive unit, the OPR complete flag ( Md.31  Status: b4) turns from OFF to ON, 
and the OPR request flag ( Md.31  Status: b3) turns from ON to OFF. 
 
Range in which the servomotor rotation 
is forcibly stopped by the stopper
Standby
OPR
Standby
Inconsistent
0
Inconsistent
Value the machine moved is stored
OP address
Inconsistent
Current feed value
t
ON
OFF
OPR speed
Creep speed
Valid torque limit range
Torque limit
ON
OFF
OPR request flag
OFF
OPR complete flag
ON
V
Near-point dog
ON
OFF
Deviation counter clear output
1)
2)
3)
4)
5) 6)
Pr.46
Pr.47
Md.34
Md.20
Md.21
Md.26
Md.31
Md.31
Pr.55
Machine feed value
Dwell time 
measurement
Machine OPR start 
(Positioning start signal) 
[Y10,Y11,Y12,Y13]
Status : b3
Status : b4
Axis operation 
status
Movement amount 
after near-point dog 
ON
Md.35
Deviation counter clear 
signal output time
Time out of dwell time
Torque limit setting value
OPR torque limit value
Torque limit stored 
value
Stops at stopper
Fig. 8.4 Stopper method 1) machine OPR