1   PRODUCT OUTLINE 
 
1.1.4 Outline design of positioning system 
The outline of the positioning system operation and design, using the QD75, is shown 
below. 
 
(1)      Positioning system using QD75 
 
M
PLG
Forward run 
pulse train
Reverse run 
pulse train
Drive unit
Servomotor
Devia-
tion 
counter
D/A 
converter
Speed 
command
Interface
Feedback pulse
Positioning module
QD75
Setting 
data
CPU module
Program
Read, write, etc.
GX Configurator-QP
Read, write, etc.
Read, write, etc.
Peripheral 
devices 
interface
Servo 
amplifier
 
Fig. 1.2 Outline of the operation of positioning system using QD75 
 
(a)      Positioning operation by the QD75 
1)  The QD75 output is a pulse train. 
The pulse train output by the QD75 is counted by and stored in the 
deviation counter in the drive unit. 
The D/A converter outputs an analog DC current proportionate to the 
count maintained by the deviation counter (called "pulse droop").    The 
analog DC current serves as the servomotor speed control signal. 
2)  The motor rotation is controlled by the speed control signal from the 
drive unit. 
As the motor rotates, the pulse encoder (PLG) attached to the motor 
generates feedback pulses, the frequency of which is proportionate to 
the rotation speed. 
The feedback pulses are fed back to the drive unit and decrements the 
pulse droop, the pulse count maintained by the deviation counter. 
The motor keeps on rotating as the pulse droop is maintained at a 
certain level. 
3)  When the QD75 terminates the output of a pulse train, the motor 
decelerates as the pulse droop decreases and stops when the count 
drops to zero. 
Thus, the motor rotation speed is proportionate to the pulse frequency, 
while the overall motor rotation angle is proportionate to the total 
number of pulses output by the QD75. 
Therefore, when a movement amount per pulse is given, the overall 
movement amount can be determined by the number of pulses in the 
pulse train. 
The pulse frequency, on the other hand, determines the motor rotation 
speed (feed speed).