Справочник Пользователя для Mitsubishi Electronics QD75P1

Скачать
Страница из 860
 
 
 
12 - 78 
MELSEC-Q
12   CONTROL SUB FUNCTIONS 
 
12.7.2 Skip function 
The "skip function" is used to stop (deceleration stop) the control of the positioning 
data being executed at the time of the skip signal input, and execute the next 
positioning data.   
A skip is executed by a skip command ( Cd.37   Skip command) or external command 
signal.  
The "skip function" can be used during control in which positioning data is used.   
 
The details shown below explain about the "skip function".   
  [1] Control details 
  [2] Control precautions 
    [3] Setting the skip function from the CPU module 
    [4] Setting the skip function using an external command signal 
 
[1]   Control details 
The following drawing shows the skip function operation. 
 
 
Fig. 12.43 Operation when a skip signal is input during positioning control 
 
[2]   Control precautions 
(1)  If the skip signal is turned ON at the last of an operation, a deceleration stop 
will occur and the operation will be terminated.   
(2)  When a control is skipped (when the skip signal is turned ON during a 
control), the positioning complete signals (X14, X15, X16, X17) will not turn 
ON.  
(3)  When the skip signal is turned ON during the dwell time, the remaining dwell 
time will be ignored, and the next positioning data will be executed.   
(4)  When a control is skipped during interpolation control, the reference axis 
skip signal is turned ON. When the reference axis skip signal is turned ON, 
a deceleration stop will be carried out for every axis, and the next reference 
axis positioning data will be executed.   
(5)  The M code ON signals (X4, X5, X6, X7) will not turn ON when the M code 
output is set to the AFTER mode (when "1: AFTER mode" is set in 
"   Pr.18   M code ON signal output timing").   
(In this case, the M code will not be stored in "   Md.25   Valid M code".)   
(6)  The skip cannot be carried out by the speed control and position-speed 
switching control. 
(7)  If the skip signal is turned ON with the M code signal turned ON, the 
transition to the next data is not carried out until the M code signal is turned 
OFF.