Appendix 10.12 History monitor function 
This function monitors starting history, error history, and warning history stored in the 
buffer memory of the QD75 during operation. 
 
[1]  Starting history 
 
Sixteen starting history logs of operations such as positioning operation, JOG 
operation, and manual pulse generator operation can be monitored. When the number 
of logs exceeds 16, the latest log overwrites the oldest log so that the latest 16 logs 
can be monitored all the time. This function allows users to check the operation 
sequence (whether the operations have been started in a predetermined sequence) at 
system start-up. 
 
 
 
To monitor the starting history, register the QD75 to the "Intelligent Function Module 
Monitor Window". 
For details on the registration method and monitoring method, refer to the following.   
GX Works2 Version1 Operating Manual (Intelligent Function Module)