Справочник Пользователя для Mitsubishi Electronics QD75P1N

Скачать
Страница из 860
 
 
 
5 - 24 
MELSEC-Q
5      DATA USED FOR POSITIONING CONTROL 
 
Item 
Setting value, setting range 
Default 
value 
Setting value buffer memory 
address 
Value set with peripheral device
Value set with sequence 
program 
Axis 1  Axis 2  Axis 3 Axis 4
 Pr.7  
Bias speed at start 
The setting range differs depending on the "   Pr.1   Unit setting".
Here, the value within the [Table 1] range is set.   
 
 [Table 1] on next page
 

156 
157 
306
307
456
457
 
 Pr.7   Bias speed at start 
Set the bias speed (minimum speed) upon starting.    The bias speed has to be 
defined to allow the motor to start smoothly especially when a stepping motor is 
used.    (A stepping motor will not start smoothly if a low rotation speed is 
instructed at the beginning.) 
The specified "bias speed at start" will be valid during the following operations: 
• Positioning operation 
• OPR operation 
• JOG operation 
 
Note that the bias speed should not exceed "   Pr.8   Speed limit value". 
 
  Precautions for using a stepping motor 
 
(1)  For the system that uses a stepping motor, executing the S-curve 
acceleration/deceleration may cause step-out. 
Before using the S-curve acceleration/deceleration, confirm that step-out does 
not occur. 
(2)  In the system that uses a stepping motor, the circular interpolation control 
cannot be carried out. 
Although setting the bias speed at start is required by the characteristics of the 
stepping motor, the setting of the bias speed at start is disabled for circular 
interpolation control. 
Ensure to use a servomotor for both 2 axes when the circular interpolation 
control is carried out. 
 
 
5.2.2  Basic parameters 2 
Item 
Setting value, setting range 
Default 
value 
Setting value buffer memory 
address 
Value set with peripheral device
Value set with sequence 
program 
Axis 1  Axis 2  Axis 3 Axis 4
 Pr.8  
Speed limit value 
The setting range differs depending on the "   Pr.1   Unit setting".
Here, the value within the [Table 2] range is set. 
 
 [Table 2] on next page
 
200000 
10 
11 
160 
161 
310
311
460
461
 Pr.9  
Acceleration time 0 
1 to 8388608 (ms) 
1 to 8388608 (ms) 
1000 
12 
13 
162 
163 
312
313
462
463
 Pr.10  
Deceleration time 0 
1 to 8388608 (ms) 
1 to 8388608 (ms) 
1000 
14 
15 
164 
165 
314
315
464
465