5 - 90 
MELSEC-Q
5      DATA USED FOR POSITIONING CONTROL 
 
5.6.2 Axis monitor data   
Storage item 
Storage details 
 
 
 
 
 
 Md.20   Current feed value 
The currently commanded address is stored.   
(Different from the actual motor position during operation) 
The current position address is stored. 
If "degree" is selected as the unit, the addresses will have a ring structure for values 
between 0 and 359.99999 degrees. 
 Update timing : 0.9ms (QD75P N/QD75D N), 1.8ms (QD75P /QD75D ) 
 The OP address is stored when the machine OPR is completed. 
 When the current value is changed with the current value changing function, the 
changed value is stored. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Md.21   Machine feed value 
The address of the current position according to the machine coordinates will be 
stored. (Different from the actual motor position during operation)   
Note that the current value changing function will not change the machine feed 
value. 
Under the speed control mode, the machine feed value is constantly updated 
always, irrespective of the parameter setting. 
The value will not be cleared to "0" at the beginning of fixed-feed control. 
Even if "degree" is selected as the unit, the addresses will not have a ring structure 
for values between 0 and 359.99999 degrees. 
 Machine coordinates: Characteristic coordinates determined with machine 
 Update timing: 0.9ms (QD75P N/QD75D N), 56.8ms (QD75P /QD75D ) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Md.22   Feedrate 
The command output speed of the operating workpiece is stored. (May be different 
from the actual motor speed during operation) 
 During interpolation operation, the speed is stored in the following manner. 
Reference axis 
: Composite speed or reference axis speed   
(Set with   Pr.20 ) 
Interpolation axis  : 0 
 Update timing: 0.9ms (QD75P N/QD75D N), 56.8ms (QD75P /QD75D ) 
 
 
 
 
 
 
 
 
 
 Md.23   Axis error No. 
When an axis error is detected, the error code corresponding to the error details is 
stored. 
 The latest error code is always stored. 
(When a new axis error occurs, the error code is overwritten.) 
 When "   Cd.5   Axis error reset" (axis control data) turns ON, the axis error No. 
is cleared (set to 0).